background image

 

 

 

 

HS 6508 
2D-Code Handscanner 

Quick Start Guide 

 

 

Version 1.1 

Summary of Contents for HS 6508

Page 1: ...HS 6508 2D Code Handscanner Quick Start Guide Version 1 1 ...

Page 2: ...ng the codes You can find more in the document Users Guide which you can find on our home page www leuze com Content QUICK START GUIDE 1 PREAMBLE 2 CONTENT 2 DELIVERY HS 6508 XX 4 PARTS 4 INSTALLATION 5 CONNECT THE HAND HELD SCANNER 5 Switching off the computer 5 Connect the cable from HS 6508 5 How to scan 6 TESTING THE SCANNER 6 TECHNICAL DATA 7 PINNING OF THE CABLES 7 KB 232 1 HS65x8 Part No 50...

Page 3: ... 13 Initial Operation 13 HS 6508 AT USB INTERFACE KEYBOARD EMULATION 14 Initial Operation 14 HS 6508 AT USB INTERFACE COM PORT EMULATION 15 Initial Operation 15 CODE 2 5 INTERLEAVED 16 DATA TRANSMISSION WITH SUFFIX ENTER 17 MORE INFORMATION TO PARAMETERIZATION YOU WILL FIND IN 18 TROUBLESHOOTING 18 OVERVIEW TYPES AND ACCESSORIES 19 CONNECTION TO LEUZE MULTINET PLUS 20 CONNECTION TO FIELDBUSES WITH...

Page 4: ...uide HS 6508 Page 4 Delivery HS 6508 xx Handheldscanner HS 6508 DPM Leaflet for Quick Start Parts The model designation is on the Top panel References to standards are located on the bottom side Connection for cable ...

Page 5: ...erside of the hand scanner until the cable snapped Fold the 2 halves of the strain relief back Attach the strain relief on the scanner by tightening the 2 Phillips screws Further steps Connect the interface cable to the appropriate socket on the computer You may need a power supply to the power supply or you can use a cable in which the tension of the computer system is used Use the pin assignment...

Page 6: ...o that the camera is aligned with the center of the code The scanner cannot recognize the label correctly if it is not completely covered by the camera and recorded Cross the red line is smaller and narrower when the scanner is closer to the code Smaller codes should be read with a smaller reading distance with larger codes the distance chosen such that the camera can be fully grasp it Testing the...

Page 7: ...ready Output with 5 Volt 7 CTS Clear to send 8 RTS Request to send 9 VCC IN 4 75 5 25 Volt DC KB 232 2 HS65x8 Part No 50120434 Coiled cable with a length of 2 8 meters Stretched Pinning 9 pin D sub connector female for cable CBA R02 C09PAR PIN Number Signal Description 1 nc Not connected 2 TX Transmit Data 3 RX Recieve Data 4 nc Not connected 5 GND Signal Ground 6 DTR Data set ready Output with 5 ...

Page 8: ...Ground Reading distances Codetype Modul size Modul size from mm to mm Code 39 3 mil 0 076 mm 27 9 40 6 Code 39 5 mil 0 127 mm 0 88 9 Code 39 7 5 mil 0 19 mm 0 137 2 Code 39 20 mil 0 508 mm 27 9 233 7 UPC EAN 13 100 0 33 mm 20 3 157 5 PDF 417 6 67 mil 0 169 mm 0 94 0 PDF 417 10 mil 0 254 mm 0 114 3 PDF 417 15 mil 0 381 mm 0 142 2 Data Matrix Code 4 mil 0 102 mm 25 4 53 3 Data Matrix Code 5 mil 0 12...

Page 9: ...e trigger button to read the code The configuration is then immediately active A second option is to configure the hand scanner with USB and RS232 interface using the PC program ESP This program lets you download and install from our website www leuze de With the program settings can be made and transmitted to the hand held scanner The configuration can also be stored so that later it can be reuse...

Page 10: ...pin assignment of the 9 pin D sub connector female can be found on page 7 Please connect the HS 6508 in accordance with the illustration RS 232 with 9600 Baud 8 Data bit 1 Stopbit No Parity no Prefix and Postfix Parameterization for Leuze Standard Protocol Leuze Standard Protocol RS 232 with 9600 Baud 8 Data bit 1 Stopbit No Parity Prefix STX and Postfixes CR LF Code 2 5 Interleaved with 10 digits...

Page 11: ...et Gateway Initial Operation Open the MA 200i Install the KB JST HS 300 with the high strength cable gland through the threaded hole and connect the 12 pin JST connector plug Connect the cable to the connector at the handheld scanner Connect the 9 pin D sub connector on the KB JST HS 300 Set on the address selection switch the address Plug in the fieldbus connection cables Connect the Power to the...

Page 12: ...ired parts 1x 50120442 HS 6508 DPM 1x 50120436 KB 232 2 HS65x8 1x 50035421 KB 021 Z 1x 50030481 MA 21 100 Connection KB021 Z Color Signal Terminal in MA 21 Brown RXD 26 White TXD 27 Blue GND 28 Red VCC 30 Black GND 31 bare shield PE 21 Please connect the HS 6508 according to the figure below Parameterization For connection to MA21 in default ...

Page 13: ...0438 KB PS2 1 HS 65x8 Please connect the HS 6508 according to the figure below Initial Operation Please do the following 1 Power down the PC 2 Disconnect the keyboard from the PC 3 Connect the Handheldscanner HS 6508 between the keyboard and the PC with the PS 2 Wedge cable 4 The Scanner send a Beep as acknowledge 5 Open a Program on the PC Notepad Editor or another Word processing program 6 Scan ...

Page 14: ...programs Required parts 1x 50120442 HS 6508 DPM 1x 50120432 KB USB 1 HS 65x8 Please connect the HS 6508 according to the figure below Initial Operation Please do the following 1 Connect the Handheldscanner HS 6508 to a free USB Port 2 The Scanner send a Beep as acknowledge 3 Open a Program on the PC Notepad Editor or another Word processing program 4 Scan the code below 5 Scan for testing a Barcod...

Page 15: ...rther processed Required parts 1x 50120442 HS 6508 DPM 1x 50120432 KB USB 1 HS 65x8 Please connect the HS 6508 according to the figure below Initial Operation Please do the following 1 Connect the Handheldscanner HS 6508 to a free USB Port 2 The Scanner send a Beep as acknowledge 3 Scan the code below 4 Install usbcdc inf the USB serial driver when prompted by Windows 5 Open a Terminalprogram or y...

Page 16: ...r number of digit can also be read please read for this the following Configurationbarcode Please note that decoding security can be increased in 2 5 interleaved codes by a check digit This check can be activated with the following bar code The check digit validation will be switched off again please scan code This check digit should be also transferred is to scan the following bar code The check ...

Page 17: ...he HS 65x8 DPM for data transmission before RS 232 USB Keyboard Emulation PS2 Keyboard Emulation If the data can be transmitted but an enter character or CR LF or newline is missing you can with the following codes it can be added Scan all codes in the printed order please 1 2 3 4 5 6 ...

Page 18: ...6508 to the end cap of the handle with an appropriate tool Remove the wire tie and pull out the cable Run the cable back on again and make sure that it is properly seated in the cradle Insert the wire tie back and fix everything with screws 5 If the scanner does not despite all the measures taken to be ready replace the power supply with another recommended power supply device from which you know ...

Page 19: ...120432 KB USB 1 HS 65x8 USB Kabel gerade 2 8m USB cable straight 2 8 m CBA U12 C09ZAR X 50120434 KB RS 232 2 HS65x8 RS232 Kabel ext spiral 2 8m RS232 cable colied 2 8m CBA R02 C09PAR 50120436 KB RS 232 1 HS65x8 RS232 Kabel PIN9 spiral 2 8m RS232 cable PIN9 colied 2 8m CBA R36 C09ZAR X 50120438 KB PS2 1 HS65x8 PS2 Kabel spiral 2 8m PS2 cable for colied 2 8 m CBA K02 C09PAR X 50120428 Netzteil für H...

Page 20: ...ieldbuses with MA 200i MA 204i Profibus Gateway Part No 501 12 893 or MA 208i Ethernet Gateway Part No 501 12 892 or MA 248i Profinet Gateway Part No 501 12 891 KB JST HS 300 Connection cable MA 21 to Rs232 Connector Part No 500 35 421 Leuze electronic GmbH Co KG Postfach 1111 In der Braike 1 D 73277 Owen Teck Tel 49 07021 573 0 Fax 49 07021 573199 E mail info leuze de http www leuze de TD_HS6508_...