Page 1: ...The installer s choice cdvigroup com SOLARPW SOLARPB STARPW STARPB SOLARPW STARPW SOLARPB STARPB Lector de proximidad Wiegand 125 kHz Wiegand 125 kHz Proximity Readers ESPAÑOL ES ENGLISH EN ...

Page 2: ... Fuentes de alimentación ADC335 y BS60 siempre que el lector no esté ali mentado por el control de accesos o el controlador de puerta INTBUSW Entorno Si los lectores están en un entorno cercano al mar o salino se recomienda barni zar los bornes para prevenir la oxidación Este producto se suministra con un varistor Un varistor regula las sobre tensiones causadas por la bobina de una cerradura en su...

Page 3: ...zas necesarias están incluidas en la caja del producto Utilice las herramientas adecuadas para cada tipo de instalación taladro destornilladores cinta métrica y siga las instrucciones de montaje del lector 1 3 2 Fig A Fig B Fig C 3 Coloque los tacos pase el cableado y haga las conexiones según el esquema indicado en este manual Después fije la tapa trasera a la pared con los tornillos y coloque el...

Page 4: ...apa trasera del lector comenzando por la parte inferior Fig A La junta debe sobresalir aproximadamente 2 mm por encima de la tapa trasera del lector Fig B Ref STARPW STARPB 1 3 2 Fig A Fig B Fig C 3 Coloque los tacos pase el cableado y haga las conexiones según el esquema indicado en este manual Después fije la tapa trasera a la pared con los tornillos y coloque el lector afianzándolo con el torni...

Page 5: ...4 3 2 1 ON ON ON ON 4 3 2 1 ON ON ON ON 4 3 2 1 ON ON ON ON 4 3 2 1 ON ON ON ON 4 3 2 1 ON ON ON ON 4 3 2 1 ON ON ON ON OFF 5 V ON 12 V Presentación de tarjeta DIP3 ON Tag leído El LED naranja se enciende durante 0 15 segundos y se emite un pitido antes de conti nuar con la validación Tag no leído Sin efecto 4 3 2 1 ON ON ON ON 4 3 2 1 ON ON ON ON 4 3 2 1 ON ON ON ON 4 3 2 1 ON ON ON ON 4 3 2 1 ON...

Page 6: ... desde el bit 7 al bit 0 2 Segunda paridad 1 bit paridad impar de los últimos 12 bits Bit 1 Bit 2 a bit 25 Bit 26 Paridad par de bit 2 a bit 13 Datos 24 bits Paridad impar de bit 14 a bit 25 Ejemplo para una tarjeta donde el código hexadecimal es 0100166A37 1 0001 0110 0110 1010 0011 0111 0 Paridad 1 1 6 6 A 3 7 Paridad 2 El código que se transmite en hexadecimal es 166A37 Paridad 1 0 si el número...

Page 7: ...0 0 6 6 A 3 7 Paridad 2 El código que se transmite en hexadecimal es 0166A37 Paridad 1 0 si el número de 1 desde el bit 2 al bit 15 es par 1 si el número de 1 desde el bit 2 al bit 15 es impar Paridad 2 0 si el número de 1 desde el bit 16 al bit 29 es impar 1 si el número de 1 desde el bit 16 al bit 29 es par Formato Wiegand 44 bits Formato de 44 bits hexadecimal La comunicación se efectúa por una...

Page 8: ...E CONTROL DE ACCESOS CENTAUR AJUSTES DEL LED VERDE AJUSTE DEL LED ROJO VERDE ACCESO CONCEDIDO ROJO ACCESO DENEGADO AZUL EN STAND BY SIGNIFICADO DE LED 8 NOTAS ES SOLARPW SOLARPB STARPW STARPB Lector de proximidad Wiegand 125 kHz MANUAL DE INSTALACIÓN ...

Page 9: ...r nor by the reader controller INTBUSW Recommended cables 4 twisted pairs 0 6mm AWG 24 Environment When in a humid area or close to the sea we recom mend applying varnish to the terminals to avoid oxidation This product is supplied with a varistor The varistor must be connec ted directly to the locking system terminals electric strikes electromagnet or lock operated by the device If the device fun...

Page 10: ...t there are no pieces missing from the mounting kit Use the correct tools according to the installa tion drill screwdrivers tape measure and follow the mounting instructions of the reader 1 2 Sch a Sch b fig c Sch c Foam seal 3 Insert the plastic plugs in the mounting holes connect the cable refer to wiring diagram on page 11 then fasten the reader with the TORX screw using the TORX bit Sch c Make...

Page 11: ...must be visible about 2mm on the top back of the rea der Sch b Ref STARPW STARPB 1 3 2 fig a Sch a Sch b Sch c Foam seal 3 Insert the plastic plugs in the mounting holes connect the cable refer to wiring diagram on page 11 then fasten the reader with the TORX screw using the TORX bit Sch c Make sure that the varistor is connected on the lock refer to page 8 Reminders and recommendations EN SOLARPW...

Page 12: ...Not used 3 ON Standard Pulls up 12 V or 5 V Open collector outputs OFF ON OFF ON OFF ON OFF ON ON OFF ON 4 3 2 1 ON ON ON ON 4 3 2 1 ON ON ON ON 4 3 2 1 ON ON ON ON 4 3 2 1 ON ON ON ON 4 3 2 1 ON ON ON ON 4 3 2 1 ON ON ON ON OFF 5 V ON 12 V Card swiped DIP3 ON Badge recognized the orange LED illuminates and the buzzer activates for 150 milliseconds 4 3 2 1 ON ON ON ON 4 3 2 1 ON ON ON ON 4 3 2 1 O...

Page 13: ... byte represent the last 6 digit of the code 4bit 1 digit of the code Each byte is transferred from bit 7 to bit 0 2 Second parity 1 bit odd parity for the last 12 bit Bit 1 Bit 2 to bit 25 Bit 26 Even parity on bit 2 to bit 13 Data 24 bits Odd parity on bit 14 to bit 25 Example code of the badge is 0100166A37 1 0001 0110 0110 1010 0011 0111 0 Parity 1 1 6 6 A 3 7 Parity 2 The code transmitted is ...

Page 14: ...s 00A86F1 Example B EM badge hexadecimal code 0100166A37 1 0000 0000 0001 0001 0110 1011 0110 1 Parity 1 0 0 6 6 A 3 7 Parity 2 The code transmitted in hexadecimal format is 0166A37 Parity 1 0 if the number of 1 in bit 2 to bit 15 is even 1 if the number of 1 in bit 2 to bit 15 is odd Parité 2 0 si le nombre de 1 dans bit 16 à bit 29 est impair 1 si le nombre de 1 dans bit 16 à bit 29 est pair 44 ...

Page 15: ...anagement on Centaur system GREEN LED SETTINGS RED LED SETTINGS GREEN ACCESS ALLOWED RED ACCESS DENIED BLUE STAND BY LED ACTUATION 8 NOTES EN SOLARPW SOLARPB STARPW STARPB Wiegand 125 kHz Proximity Readers INSTALLATION MANUAL ...

Page 16: ...Fax 33 0 1 48 91 21 21 CDVI FRANCE EXPORT Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI AMERICAS CANADA USA Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 73 93 00 Fax 32 0 56 73 93 05 CDVI TAIWAN Phone 886 0 42471 2188 Fax 886 0 42471 2131 CDVI SUISSE Phone 41 0 21 882 18 41 Fax 41 0 21 882 18 42 CDVI CHINA Phone 86 0 10 84606132 82 Fax 86 ...