background image

SOLARKPW

SOLARKPB 

MANUAL DE INSTALACIÓN

INSTALLATION MANUAL

 ESPAÑOL

ES

 ENGLISH

EN

Lector de doble tecnología Proximidad/Digicode

®

 - Wiegand

Range: 

Integrated Access Control /

Dual Technology Digicode

®

/Proximity Reader - Wiegand

Gama: 

Control de accesos integrado

Group Products

Summary of Contents for SOLARKPB

Page 1: ...LACIÓN INSTALLATION MANUAL ESPAÑOL ES ENGLISH EN Lector de doble tecnología Proximidad Digicode Wiegand Range Integrated Access Control Dual Technology Digicode Proximity Reader Wiegand Gama Control de accesos integrado Group Products ...

Page 2: ...a distancia máxima entre el lector y los controladores ATRIUM CENTAUR e INTBUSW no debe ser superior a 50 metros Asegúrese de que el cable de conexión del lector al controlador no pasa cerca de cables de alta tensión por ejemplo 230 Vca Se recomienda usar cable de 4 pares trenzados SYT1 8 10º AWG 20 Recomendaciones de montaje Para evitar actos vandálicos se recomienda instalar el SOLARKPW SOLARKPB...

Page 3: ...uma 6 ESQUEMA DE CABLEADO CONEXIÓN A CONTROLADOR DE PUERTA INTBUSW 7 FUNCIONAMIENTO DE LED Y BUZZER Al conectar el lector El LED verde se enciende durante 1 segundo El LED rojo se enciende durante 1 segundo El buzzer se activa durante 1 segundo Funcionamiento Activación de buzzer con 0 V Activación de LED con 0 V Modo standatd Tarjeta leída Se enciende el LED naranja y se emite un pitido durante 0...

Page 4: ...timos 12 bits Bit 1 Bit 2 a bit 25 Bit 26 Paridad par de bit 2 a bit 13 Datos 24 bits Paridad impar de bit 14 a bit 25 CÓDIGO DE TECLADO Ejemplo con un código de teclado de 4 dígitos 1 3 7 A y luego B y 1 3 7 5 y luego B 1 0000 0000 0001 0011 0111 0101 0 Directo Paridad 1 0 0 1 3 7 A Paridad 2 Hexadecimal Paridad 1 0 0 0 5 5 F Paridad 2 Ejemplo con un código de 5 dígitos 7 1 3 7 A y luego B y 7 1 ...

Page 5: ...3 7 5 y luego B 1 0001 0001 1001 1000 1010 1010 1101 0 TARJETA Paridad 1 1 1 9 8 A A D Paridad 2 CÓDIGO TECLADO Directo Paridad 1 0 6 7 1 3 7 5 Paridad 2 Hexadecimal Paridad 1 0 0 A 3 E 8 F Paridad 2 Paridad 1 0 si el número de 1 desde el bit 2 al bit 15 es par 1 si el número de 1 es impar Paridad 2 0 si el número de 1 desde el bit 16 al bit 29 es impar 1 si el número de 1 es par 10 FORMATO DE SAL...

Page 6: ...ERDE AJUSTES DEL LED ROJO SIGNIFICADO LED VERDE ACCESO CONC ROJO ACCESO DENEG AZUL EN STAND BY En modo Digicode únicamente o en modo de proximidad únicamente 11 FORMATO DE SALIDA ARK 8 BITS Entrada teclado Hexadecimal Datos binarios 0 FO 11110000 1 E1 11100001 2 D2 11010010 3 C3 11000011 4 B4 10110100 5 A5 10100101 6 96 10010110 7 87 10000111 8 78 01111000 9 69 01101001 o A 5A 01011010 o B 4B 0100...

Page 7: ...e tecnología Proximidad Digicode Wiegand MANUAL DE INSTALACIÓN 7 cdvi com cdvigroup com 13 GESTIÓN DE LED EN EL SISTEMA DE CONTROL DE ACCESOS ATRIUM SIGNIFICADO DE LED VERDE ACCESO CONCEDIDO ROJO ACCESO DENEGADO AZUL EN STAND BY 14 NOTAS ...

Page 8: ...ro de dígitos de los códigos A1 Programación del número de dígitos 1 pitido OK LED verde ON 4 pitidos Error 1 pitido LED verde ON Teclee 26 30 o 44 para indicar el número de bits de la trama Wiegand A2 Programación del número de bits Número de dígitos Los códigos de 7 y 8 dígitos se admiten sólo a 30 y 44 bits Los códigos de 8 dígitos sólo se admiten a 44 bits Modo permanente El teclado siempre pe...

Page 9: ...rde ON A7 Programación del modo de funcionamiento Teclee 0 Permanente 1 Stand by B Modo Stand By En stand by el teclado está iluminado débilmente y el lector está desactivado Al acercar una tarjeta o el dedo el lector se activa y se ilumina a la espera de validar el acceso permanece activo el tiempo indicado en el apartado A0 Acabado el tiempo de espera el lector vuelve a entrar en modo Stand By P...

Page 10: ...UM 4 4 Cable Programming your installation before installing products on site The distance between a CENTAUR and ATRIUM controllers or an INTBUSW reader interface should not exceed more than 50 meters Make sure that the cable is not near by a high voltage cables ex 230 V AC Recommended cable 2 twisted pairs SYT1 0 8MM AWG 20 Back EMF protection To secure the system from back electromagnetic fields...

Page 11: ...he Foam seal 6 WIRING CONNECTION TO A DOOR CONTROLLER INTBUSW 7 LED AUDIBLE TONE When powered up Green LED illuminates for 1 second RED LED illuminates for 1 second Blue LED illuminates for 1 second with beep for 1 second Operating mode Buzzer activated with 0V input LEDs activated with 0V input Standard Mode Badge recognized the orange LED illuminates and the beeper emits a tone during 150 millis...

Page 12: ...it 25 Bit 26 Even parity on bit 2 bit13 Data 24 bits Odd parity on bit 14 bit 25 KEYPAD CODE Example with a 4 Digit keypad code 1 3 7 A Then B 1 3 7 5 Then B 1 0000 0000 0001 0011 0111 0101 0 Direct Parity 1 0 0 1 3 7 A Parity 2 Hexadecimal Parity 1 0 0 0 5 5 F Parity 2 Example with a 5 Digit keypad code 7 1 3 7 A Then B 7 1 3 7 5 Then B Direct Parity 1 0 7 1 3 7 A Parity 2 Hexadecimal Parity 1 0 ...

Page 13: ...Parity 1 1 1 9 8 A A D Parity 2 KEYPAD CODE Direct Parity 1 0 6 7 1 3 7 5 Parity 2 Hexadecimal Parity 1 0 0 A 3 E 8 F Parity 2 Parity 1 0 if the number of 1 in bit 2 to bit 15 is even 1 if the number of 1 in bit 2 to bit 15 is odd Parity 2 0 if the number of 1 in bit 16 to bit 29 is odd 1 if the number of 1 in bit 16 to bit 29 is even 10 44 bit wiegand format 44 bit hexadecimal format The output f...

Page 14: ... RED LED SETTINGS LED ACTUATION GREEN ACCESS ALLOWED RED ACCESS DENIED BLUE STAND BY In Digicode keypad mode only or Proximity mode only 11 ARK 8 BITS OUTPUT format Keypad input Hexadecimal Binary Datas 0 FO 11110000 1 E1 11100001 2 D2 11010010 3 C3 11000011 4 B4 10110100 5 A5 10100101 6 96 10010110 7 87 10000111 8 78 01111000 9 69 01101001 ou A 5A 01011010 ou B 4B 01001011 ...

Page 15: ...N MANUAL 15 cdvi com cdvigroup com SOLARKPW SOLARKPB Dual Technology Digicode Proximity reader Wiegand 13 LED configuration on ATRIUM system LED ACTUATION GREEN ACCESS ALLOWED RED ACCESS DENIED BLUE STAND BY 14 NOTES ...

Page 16: ...g 2 short beeps Entry or Exit from programming 4 short beeps data computing error 1 beep OK Green LED ON 4 beeps Error 1 bip LED verte ON A4 Programming mode Enter 0 for hexadecimal mode A B are not used Atrium Centaur standard 26 bits 1 for decimal mode Direct mode A is allowed Centaur only Digicode protocol Program the code in the field PIN 2 for ARK mode 1 beep Green LED ON 1 beep OK Green LED ...

Page 17: ...m a user code except the A and B key Enter the user code and then B to validate the code 2 beeps are emitted Red LED ON 2 beeps are emitted 1 beep OK Green LED ON 4 beeps Error 1 beep Green LED ON A5 Programming the audible signal Enter 0 disable the keypad beeps 1 Enable the keypad beeps 1 beep OK Green LED ON 4 beeps Error 1 beep Green LED ON A6 Programming Master code Enter Enter the new master...

Page 18: ...EN 18 cdvi com cdvigroup com SOLARKPW SOLARKPB Dual Technology Digicode Proximity reader Wiegand MANUEL D INSTALLATION ...

Page 19: ...EN SOLARKPW SOLARKPB Dual Technology Digicode Proximity reader Wiegand MANUEL D INSTALLATION 19 cdvi com cdvigroup com ...

Page 20: ...vio aviso CDVI FRANCE EXPORT Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI AMERICAS CANADA USA Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 73 93 00 Fax 32 0 56 73 93 05 CDVI SUISSE Phone 41 0 21 882 18 41 Fax 41 0 21 882 18 42 CDVI CHINA Phone 86 0 10 62414516 Fax 86 0 10 62414519 CDVI IBÉRICA SPAIN PORTUGAL Phone 34 0 935 390 966 Fax 34 ...