AN-260

Using the tSec Extra Reader Card Holder

Application Note

Содержание tSec Extra

Страница 1: ...AN 260 Using the tSec Extra Reader Card Holder Application Note ...

Страница 2: ... or mechanical for any purpose without the express written permission of Integrated Control Technology Limited Designed and manufactured by Integrated Control Technology Limited Protege and the Protege Logo are registered trademarks of Integrated Control Technology Limited All other brand or product names are trademarks or registered trademarks of their respective holders Copyright Integrated Cont...

Страница 3: ...Contents Introduction 4 Prerequisites 4 Programming a Protege Door 4 Programming a tSec Reader 5 Installing the Hardware 6 AN 260 Using the tSec Extra Reader Card Holder Application Note 3 ...

Страница 4: ...g version 4 00 331 or higher Card Reader Prerequisites A tSec Extra Reader with firmware version 1 04 231 or higher ICT Card Holder Ordering Code PRX TSEC XCDH Programming Prerequisites Each reader that will be fitted with a card holder must be programmed to use the card re read function Programming a tSec Extra Reader with this functionality requires The Protege Config App OR A MIFARE programming...

Страница 5: ... Reader Config 1 Navigate to Reader Configuration and tap to add a new configuration 2 Enter a Config name such as Silent Re read Mode to identify the new configuration 3 Tap the Add TLV dropdown arrow 4 Scroll down toward the bottom of the list and select Reread Mode then tap OK 5 Tap the Reread Mode TLV dropdown arrow At the bottom of the screen select the Silent Reread option 6 Tap SAVE Once th...

Страница 6: ...e READER Reader disconnected Programming Card To program a tSec Extra Reader with card re read functionality using a programming card you will first need to obtain the necessary MIFARE programming card loaded with the Enable Silent Re read mode setting Once the required Config Card is available it can be used to easily program readers tSec Readers can only be programmed within 2 minutes of startup...

Страница 7: ...en made to ensure accuracy in the representation of this product neither Integrated Control Technology Ltd nor its employees shall be liable under any circumstances to any party in respect of decisions or actions they may make as a result of using this information In accordance with the ICT policy of enhanced development design and specifications are subject to change without notice www ict co 11 ...