8400 BaseLine D | Software Manual
Function library
Function blocks
148
L
Firmware 03.00 - DMS EN 5.0 - 07/2009
9.1.1.2
JOG setpoints
JOG setpoints are constant values which are stored in the memory under
C39/1
...
C39/3
.
The JOG setpoints can be called binary-coded using the
bJog1
...
bJog2
selection inputs
so that 3 options are available.
The main setpoint
nNSet_a
must be freely defined for
bJog1
...
bJog2
= FALSE
.
The number of selection inputs to be assigned depends on the number of JOG setpoints
required.
9.1.1.3
Setpoint inversion
The output signal of the JOG function is led via an inverter.
The sign of the setpoint changes if
bNSetInv
is set to TRUE.
Used
Main setpoint
bJog2
bJog1
FALSE
FALSE
nNSet_a
FALSE
True
C39/1
True
FALSE
C39/2
True
True
C39/3