8400 BaseLine D | Software Manual
Parameter reference
Parameter list | C00006
176
L
Firmware 03.00 - DMS EN 5.0 - 07/2009
C00006
Parameter | Name:
C00006 | Select motor control
Data type: UNSIGNED_8
Index: 24569
d
= 5FF9
h
Selection of motor control type (operating mode)
Selection list
(Lenze setting printed in bold)
Info
4 SLVC: Vector control
This control type is used for sensorless vector control of
an asynchronous motor.
• This control mode needs the motor parameters to be
set as exactly as possible!
6 VFCplus: V/f linear
This control type is used for open-loop speed control of
an asynchronous motor via a linear V/f characteristic and
represents the most simple control type.
• In order to set the V/f characteristic, the rated fre-
quency (
) and rated voltage (
) of the
motor must be entered only.
8 VFCplus: V/f quadr
This control type is used for open-loop speed control of
an asynchronous motor via a square-law V/f characteris-
tic.
• In order to set the V/f characteristic, the rated fre-
quency (
) and rated voltage (
) of the
motor must be entered only.
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1