Firmware 03.00 - DMS EN 5.0 - 07/2009
L
93
8400 BaseLine D | Software Manual
Motor control (MCTRL)
Motor selection
5.2.1
Manual parameter setting of external motors
External motor data can be entered manually if you have the equivalent circuit diagram
and nameplate data available.
Tip!
For the improvement of the concentricity factor, we recommend to carry out the
motor parameter identification of the external motor first, and then enter the data
for the manual parameterisation.
Improving the concentricity factor includes
• the adjustment of the inverter error characteristic to the drive system and
• the knowledge of the motor cable resistance.
Both factors are determined during the motor parameter identification.
Overview of the relevant parameters
[5-5]
Codes for the manual parameterisation of the motor data
Parameter
INFO
V/f base frequency
Slip compensation
Nameplate data, rated motor power
Data of the equivalent circuit diagram of the motor
Data of the equivalent circuit diagram of the motor
Nameplate data, rated motor speed
Nameplate data, rated motor current
Nameplate data, rated motor frequency
Nameplate data, rated motor voltage
Nameplate data, motor cos
ϕ
Data of the equivalent circuit diagram of the motor