Firmware 03.00 - DMS EN 5.0 - 07/2009
L
151
8400 BaseLine D | Software Manual
Function library
Function blocks
Parameter
Identifier/data type
Index
Possible settings
INFO
dnActRetain
DINT
Saves the current setpoint
nHighLimit
INT
-199.9
%
199.9 Upper limit
• Initialisation: 100.0 %
nLowLimit
INT
-199.9
%
199.9 Lower limit
• Initialisation: -100.0 %
wTir
WORD
1
0.1 s
6000 Acceleration time - main setpoint
(Tir)
• 10
≡
1 s
• Initialisation: 10 s
wTif
WORD
1
0.1 s
6000 Deceleration time Tif
• 10
≡
1 s
• Initialisation: 10 s
Function
BYTE
Function selection
• Initialisation: 0
0 No further action;
nOut_a
retains its
value.
1 The motor potentiometer returns to
0 % with the deceleration time Tif.
2 The motor potentiometer runs to
the lower limit value with the
deceleration time Tif (
nLowLimit
)
3 The motor potentiometer output
immediately changes to 0 %
Important for the emergency stop
function
4 The motor potentiometer output
immediately changes to the lower
limit value (
nLowLimit
)
5 The motor potentiometer runs to
the upper limit value with the
acceleration time Tir (
nHighLimit
)
byInitFunction
BYTE
Behaviour after mains power-up
• Initialisation: 0
0 The output value being output
during mains power-up, is saved
non-volatilely in the internal
memory of the controller. It will be
reloaded during mains power-up.
1 The lower limit (
nLowLimit
) is loaded
during mains power-up.
2 An output value = 0 % is loaded
during mains power-up.