8400 BaseLine D | Software Manual
Drive Application
Interface description of the drive application
Outputs
Identifier/data type
Information/possible settings
wDriveControlStatus
WORD
For detailed description see
Application control via a bus system is possible with the 8400 BaseLine C controller.
wCurrentFailNumber
WORD
Shows the current error numbers.
For a detailed description of the structure of error numbers see
bDriveReady
WORD
Display: Drive is ready to process setpoints.
No error occurred.
bDriveFail
BOOL
An error occurred.
The error type is as follows:
• Fault
• Trouble
• WarningLocked
bCInhActive
WORD
Display: Controller inhibit is activated
bQSPIsActive
WORD
Display: Quick stop is activated
bSpeedCcw
WORD
Display: Direction of motor rotation with respect to actual speed value.
TRUE: Motor rotates anti-clockwise (as viewed looking onto the motor shaft)
bSpeedActCompare
WORD
TRUE: The actual speed value is lower than the value set in
bImaxActive
WORD
TRUE: The controller operates at the maximum current limit
bSpeedSetReached,
bSpeedActEqSet
WORD
• bSpeedSetReached
TRUE: Speed setpoint reached.
• bSpeedSetReached
TRUE: Actual speed value has reached setpoint within one hysteresis band
nMotorCurrent_a
WORD
Output of the current motor current
nMotorSpeedSet_a,
nMotorSpeedAct_a
WORD
• nMotorSpeedSet_a:
resulting total speed setpoint.
• nMotorSpeedAct_a:
actual speed value
nMotorTorqueAct_a
WORD
Current actual torque value
nDCVoltage_a
WORD
Actual DC-bus voltage
nMotorVoltage_a
WORD
Currently applied motor voltage