Salicru EQUINOX BATT EQX2 BATT Скачать руководство пользователя страница 1

EQX2 BATT 

ES

EN

MANUAL DE USUARIO

BATERÍAS MODULARES PARA INVERSORES SOLARES

Содержание EQUINOX BATT EQX2 BATT

Страница 1: ...EQX2 BATT ES EN MANUAL DE USUARIO BATER AS MODULARES PARA INVERSORES SOLARES...

Страница 2: ...2 SALICRU...

Страница 3: ...LISTA DE CONTENIDO 5 INSTALACI N 5 1 UBICACI N 5 1 1 Ubicaci n de la instalaci n 5 2 PROCESO DE MONTAJE 5 2 1 Instalaci n de la base 5 2 2 Instalaci n del m dulo 5 2 3 Conexi n del tierra 5 3 CONEXI N...

Страница 4: ...ar de que no se han escatimado esfuerzos para garan tizar que la informaci n de este manual de usuario sea com pleta y precisa no nos hacemos responsables de los errores u omisiones que pudieran exist...

Страница 5: ...udiendo recaer sobre la misma persona la responsabilidad de realizar las respectivas acciones al actuar en nombre o representaci n del mismo 3 2 NOTAS DE SEGURIDAD 1 Antes de la instalaci n leer con a...

Страница 6: ...ninguna parte interna de la bater a hasta 5 minutos despu s de haber sido desconectada Marca CE el inversor cumple con los requisitos de las directrices CE aplicables Certificaci n SGS Certificaci n...

Страница 7: ...e potencia utilizados en sistemas de potencia fotovoltaicos Parte 2 Requisitos particulares para inversores Compatibilidad electromagn tica IEC EN UNE 61000 6 2 2005 Compatibilidad electromag n tica C...

Страница 8: ...Wh Capacidad de la bater a Tecnolog a de la bater a Nombre serie 5 1 4 Condiciones de almacenamiento El inversor debe de almacenarse en su embalaje original La temperatura y humedad deber a estar entr...

Страница 9: ...Elementos contenidos en el embalaje tem Descripci n Cantidad 1 M dulo de Control 1 2 M dulo de Bater a 2 10 3 Base 1 4 Fijadores 2 5 Tornillos de fijaci n 40 6 Tornillos y tacos de expansi n 4 7 Cone...

Страница 10: ...er as mientras est n en funcionamiento e ins talarlas fuera del alcance de los ni os 6 1 1 Ubicaci n de la instalaci n La ubicaci n recomendada para las bater as de los inver sores h bridos es en inte...

Страница 11: ...ujeros en la pared Fig 13 Marcar la posici n 4 Extraer el m dulo de control Fig 14 Extracci n del m dulo de control 5 Usar un taladro el ctrico con una broca de 10 mm de di metro para perforar 4 aguje...

Страница 12: ...a es necesaria para re sistir una sobretensi n y mejorar el rendimiento de EMI Labater adebeestarcorrectamenteconectadaatierra Para un sistema con una sola bater a el cable PE debe conectarse a tierra...

Страница 13: ...imentaci n positiva la l nea de alimentaci n negativa el cable de comunicaci n y el cable de tierra entre el inversor y el m dulo de control La imagen de esta p gina muestra la conexi n de los cables...

Страница 14: ...sor antes de salir de f brica insertar el otro extremo en el puerto Inverter COM del m dulo de control en el momento de la instalaci n Interfaz de comunicaci n y definici n Item Service Com Inverter C...

Страница 15: ...stema completo para cargar al 100 el conjunto de bater as ABCD 11 Desconectar los paneles y utilizar las propias cargas de la instalaci n para descargar todo el conjunto de bater as ABCD el ajuste de...

Страница 16: ...DC y CA y la realizar un auto test y si todo es normal comenzar a funcionar de acuerdo con el modo de trabajo que configur en la aplicaci n La pantalla y los indicadores del inversor mostrar n los pa...

Страница 17: ...Comprobar si la luz es normal Inspecci n visual Warning 3 Cable Aislamiento terminal Fallo aislamiento envejecimiento el terminal est pelado o corro do Reemplazar el cable reemplazar la placa de termi...

Страница 18: ...o Kg 110 9 143 2 175 5 207 8 240 1 272 4 304 7 337 369 3 Dimensiones mm F 315 An 708 Alt 616 776 936 1096 1256 1416 1576 1736 1896 Grado de protecci n IP54 Ciclos de vida 6000 ciclos 80 C DOD Rango de...

Страница 19: ...19 ES EQX2 INVERSORES SOLARES DE CONEXI N A RED MANUAL DE USUARIO...

Страница 20: ...alautordera BARCELONA Tel 34 93 848 24 00 sst salicru com SALICRU COM www linkedin com company salicru salicru_SA Gama de Productos Sistemas de Alimentaci n Ininterrumpida SAI UPS Estabilizadores Redu...

Страница 21: ...EQX2BATT EN USER MANUAL MODULAR BATTERIES FOR SOLAR INVERTERS...

Страница 22: ...22 SALICRU...

Страница 23: ...1 STATEMENT BY THE MANAGEMENT 4 2 STANDARDS 4 3 ENVIRONMENT 5 PRODUCT DESCRIPTION 5 1 BASIC FEATURES 5 1 1 Function 5 1 2 Models 5 1 3 Naming convention 5 1 4 Storage conditions 5 2 DIAGRAMS 5 2 1 Con...

Страница 24: ...e to guarantee that the information in this user manual is complete and accurate we are not responsible for any errors or omissions that may be present The images included in this document are for ill...

Страница 25: ...sponding actions whereby the responsibility for carrying out the respective actions may be held by the same person when they act on behalf or in representation of the installer or operator 3 2 NOTES O...

Страница 26: ...installation Do not touch any internal part of the battery for 5 minutes after it has been disconnected CE marking the inverter meets the requirements of the applicable CE directives SGS certification...

Страница 27: ...verters for use in photovoltaic power systems Part 2 Particular require ments for inverters Electromagnetic compatibility IEC EN UNE 61000 6 2 2005 Electromagnetic compat ibility EMC Part 6 2 Generic...

Страница 28: ...tion EQX2 Li Ion BATT 5 kWh Battery capacity Battery technology Serial name 5 1 4 Storage conditions The inverter must be stored in its original packaging The temperature and humidity should be betwee...

Страница 29: ...Items included in the packaging Item Description Quantity 1 Control module 1 2 Battery module 2 10 3 Base 1 4 Fastening elements 2 5 Fixing screws 40 6 Screws and expansion plugs 4 7 Battery connector...

Страница 30: ...tween 0 C and 50 C 6 Do not touch the batteries during operation and install them out of the reach of children 6 1 1 Installation location We recommend installing the batteries of hybrid inverters ind...

Страница 31: ...late to mark the position of 4 holes in the wall Fig 13 Marking the position 4 Remove the control module Fig 14 Removing the control module 5 Use an electric drill with a 10 mm diameter drill bit to d...

Страница 32: ...ion Warning A suitable earthing connection is necessary to with stand overvoltages and improve EMI performance The battery must be properly earthed For systems with a single battery the PE cable must...

Страница 33: ...n has been completed the positive power line the negative power line the communication cable and the earthing cable must be connected between the inverter and the control module The picture on this pa...

Страница 34: ...stalled in the inverter before leaving the factory Insert the other end into the Inverter COM port of the control module during installation Communication interface and definition Item Service Com Inv...

Страница 35: ...m to fully charge the ABCD battery pack 11 Disconnect the panels and use the system s loads to discharge the entire ABCD battery pack the inverter s On Grid DOD screen should still be set at 95 as des...

Страница 36: ...m a self test and if everything is OK it will start operating according to the work mode you configured in the application The inverter s screen and LEDs will display the relevant parameters and their...

Страница 37: ...ke sure that the light is normal Visual inspection Warning 3 Cable Insulation terminal Insulation defect ageing terminal stripped or corroded Replace the cable replace the terminal board Tab 7 Points...

Страница 38: ...25 Weight kg 110 9 143 2 175 5 207 8 240 1 272 4 304 7 337 369 3 Dimensions mm D 315 W 708 H 616 776 936 1096 1256 1416 1576 1736 1896 Degree of protection IP54 Life cycles 6000 cycles 80 C DOD Charg...