Parameter setting and diagnosing directly at the controller
3.2.3
Messages
The current status of the controller is constituted via
ƒ six coloured LEDs, see
Signalling of the LEDs "D" and "E"
ƒ messages:
Message
Meaning
PASS
Password input
CAL
blinking
Identification is in progress. Operation is not enabled yet.
CAL / Stop
alternatively blinking
Identification is ready to start
CAL / Err
alternatively blinking
Identification is not ready to start. Either C088, or C089, or
C090 is 0.
bF
blinking
Identification error. Drive ID stored in EMP does not match
the drive ID stored in the controller.
CL
constant
CL: Clamp
Current limit set in C022 is reached.
FCL
constant
Fast current limit value (higher than value set in C022) is
reached
FSt
constant
Flying start is in progress
dec
constant
Deceleration is temporarily suspended because of higher bus
voltage
br
flashes during the hold time of the
DC brake
DC brake is in progress