Firmware 03.00 - DMS EN 5.0 - 07/2009
L
15
8400 BaseLine D | Software Manual
Product description
Communicating with the controller
Preconditions:
The diagnostic adapter is connected to diagnostic interface X6 on the controller and to
a free USB port on the PC.
The driver required for the diagnostic adapter is installed.
The controller is supplied with mains power via X100.
How to build up an online connection via the diagnostic adapter:
1. Select the 8400 BaseLine controller to which you want to build up an online
connection in the
Project view
of the »Engineer«:
2. Click the icon or select the command
Online
Go online
.
• If no online connection has been configured for the selected controller so far,
the
Device assignment offline devices
dialog box will be displayed:
• The dialog box also appears if the online connection is built up via the command
Online
Go online
instead of using the
toolbar
icon.
3. Select the "Diagnostic adapter" entry from the
Bus connection
list field.
Stop!
If you change parameters in the »Engineer« while the controller is connected
online, the changes will be directly accepted by the controller!