Firmware 03.00 - DMS EN 5.0 - 07/2009
L
197
8400 BaseLine D | Software Manual
Parameter reference
Parameter list | C00170
C00170
C00171
C00173
C00174
C00177
Parameter | Name:
C00170 | Error counter
Data type: UNSIGNED_8
Index: 24405
d
= 5F55
h
Display of the error counter for the 8 errors occurred last
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C00170/1
Error counter - history 1
C00170/2
Error counter - history 2
C00170/3
Error counter - history 3
C00170/4
Error counter - history 4
C00170/5
Error counter - history 5
C00170/6
Error counter - history 6
C00170/7
Error counter - history 7
C00170/8
Error counter - history 8
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00171 | Logbook access index
Data type: UNSIGNED_8
Index: 24404
d
= 5F54
h
This code is used internally by the controller and must not be overwritten by the user!
Parameter | Name:
C00173 | Mains voltage
Data type: UNSIGNED_8
Index: 24402
d
= 5F52
h
Selection of the mains voltage for operating the device.
Selection list
(Lenze setting printed in bold)
Info
0 3ph 400V / 1ph 230V
3-phase 400 V or 1-phase 230 V
1 3ph 440V / 1ph 230V
3-phase 440 V or 1-phase 230 V
2 3ph 480V / 1ph 230V
3-phase 480 V or 1-phase 230 V
3 3ph 500V / 1ph 230V
3-phase 500 V or 1-phase 230 V
;
Read access
;
Write access
;
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00174 | Reduced brake chopper threshold
Data type: UNSIGNED_8
Index: 24401
d
= 5F51
h
The threshold from which on the brake chopper is controlled is reduced by the voltage value set here.
Setting range
(min. value | unit | max. value)
Lenze setting
0
V
150
0 V
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00177 | Switching cycles
Data type: UNSIGNED_32
Index: 24398
d
= 5F4E
h
Counter of different switching cycles and stressful situations
Display range
(min. value | unit | max. value)
0
2147483647
Subcodes
Info
C00177 /1
Number of mains switching cycles
C00177 /2
Number of the switching cycles of the output relay
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 1