8400 BaseLine D | Software Manual
Parameter reference
Parameter list | C00228
200
L
Firmware 03.00 - DMS EN 5.0 - 07/2009
C00228
C00231
C00234
C00235
C00236
Parameter | Name:
C00228 | L_PCTRL_1: deceleration time
Data type: UNSIGNED_32
Index: 24347
d
= 5F1B
h
From version 03.00.00
FB
: Deceleration time for the output value of the PID process controller
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
s
999.9
0.1 s
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1000
Parameter | Name:
C00231 | L_PCTRL_1: Operating range
Data type: INTEGER_16
Index: 24344
d
= 5F18
h
From version 03.00.00
FB
: Operating range for the PID process controller
Setting range
(min. value | unit | max. value)
0.0
%
199.9
Subcodes
Lenze setting
Info
C00231/1
199.9 %
L_PCTRL_1: Pos. maximum
C00231/2
0.0 %
L_PCTRL_1: Pos. minimum
C00231/3
0.0 %
L_PCTRL_1: Neg. minimum
C00231/4
199.9 %
L_PCTRL_1: Neg. maximum
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00234 | Oscillation damping influence
Data type: UNSIGNED_16
Index: 24341
d
= 5F15
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
250
5 %
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00235 | Filter time - oscill. damping
Data type: UNSIGNED_8
Index: 24340
d
= 5F14
h
This code is used internally by the controller and must not be overwritten by the user!
Parameter | Name:
C00236 | Oscill. damping - field weakening
Data type: UNSIGNED_8
Index: 24339
d
= 5F13
h