Firmware 03.00 - DMS EN 5.0 - 07/2009
L
103
8400 BaseLine D | Software Manual
Motor control (MCTRL)
DC-injection braking
Explanation of the automatic DC-injection braking function by means of two examples
Example 1
[5-3]
Example 1: Signal characteristic for automatic DC-injection braking
Example 2
[5-4]
Example 2: Signal characteristic for automatic DC-injection braking
:
Speed setpoint
:
Actual speed value of the motor
:
Controller output current
:
Pulse inhibit
:
DC-injection braking is active
c
:
The motor rotates with the selected
speed. The resulting current depends
on the load
.
d
:
The DC braking current set in
injected.
e
:
expired, the pulse inhibit is set.
0
1
5
2
3
4
C0106
C00036
C00019
^
:
Speed setpoint
:
Actual speed value of the motor
:
Controller output current
:
Pulse inhibit
:
DC-injection braking is active
c
:
The motor rotates with the selected
speed. The resulting current depends
on the load
.
d
:
The DC braking current set in
injected.
e
:
The actual speed value of the motor
follows the speed setpoint. The
resulting current depends on the
load.
0
1
5
2
3
4
C00036