background image

Generator image used for illustration purposes only

1 of 5

Industrial Diesel Generator Set

EPA Certified Stationary Emergency

500 kW Diesel

Standby Power Rating

625kVA    500kW    60Hz

features

benefits

primary codes and standards

Generator Set

=

  PROTOTYPE & TORSIONALLY TESTED 

4

 

PROVIDES A PROVEN UNIT

=

  UL2200 TESTED 

4

 

ENSURES A QUALITY PRODUCT

=

  RHINOCOAT PAINT SYSTEM 

4

 

IMPROVES RESISTANCE TO ELEMENTS

=

  WIDE RANGE OF ENCLOSURES AND TANKS 

4

 

PROVIDES A SINGLE SOURCE SOLUTION

Engine

=

  EPA COMPLIANT 

4

 

MEETS EPA STANDARDS

=

  INDUSTRIAL TESTED, GENERAC APPROVED 

4

 

ENSURES INDUSTRIAL STANDARDS

=

  POWER-MATCHED OUTPUT 

4

 

ENGINEERED FOR PERFORMANCE

=

  INDUSTRIAL GRADE 

4

 

IMPROVES LONGEVITY AND RELIABILITY

Alternator

=

  TWO-THIRDS PITCH 

4

 

ELIMINATES HARMFUL 3RD HARMONIC

=

  LAYER WOUND ROTOR & STATOR 

4

 

IMPROVES COOLING

=

  CLASS H MATERIALS 

4

 

HEAT TOLERANT DESIGN

=

  DIGITAL 3-PHASE VOLTAGE CONTROL 

4

 

FAST AND ACCURATE RESPONSE

Controls

=

  ENCAPSULATED BOARD W/ SEALED HARNESS 

4

 

EASY, AFFORDABLE REPLACEMENT

=

  4-20mA VOLTAGE-TO-CURRENT SENSORS 

4

 

NOISE RESISTANT 24/7 MONITORING

=

  SURFACE-MOUNT TECHNOLOGY 

4

 

PROVIDES VIBRATION RESISTANCE

=

  ADVANCED DIAGNOSTICS & COMMUNICATIONS 

4

 

HARDENED RELIABILITY

SD500

Содержание SD500

Страница 1: ... COMPLIANT 4 MEETS EPA STANDARDS INDUSTRIAL TESTED GENERAC APPROVED 4 ENSURES INDUSTRIAL STANDARDS POWER MATCHED OUTPUT 4 ENGINEERED FOR PERFORMANCE INDUSTRIAL GRADE 4 IMPROVES LONGEVITY AND RELIABILITY Alternator TWO THIRDS PITCH 4 ELIMINATES HARMFUL 3RD HARMONIC LAYER WOUND ROTOR STATOR 4 IMPROVES COOLING CLASS H MATERIALS 4 HEAT TOLERANT DESIGN DIGITAL 3 PHASE VOLTAGE CONTROL 4 FAST AND ACCURAT...

Страница 2: ...em Oil Filter Type Full Flow Cartridge System Voltage 24VDC Crankcase Capacity L Gal 60 15 8 Battery Charging Alternator 70 Amps at 24V Battery Size at 0ºC 1155 CCA Battery Group 8D Battery Voltage 2 12VDC Ground Polarity Negative ALTERNATOR SPECIFICATIONS Standard Model WEG Voltage Regulator Type Digital Poles 4 Number of Sensed Phases All Field Type Revolving Regulation Accuracy Steady State 1 I...

Страница 3: ...ze 2 832 757 1136 1514 1893 2271 2650 Upsize 2 723 571 857 1143 1429 1714 2000 Fuel Consumption Rates STANDBY Fuel Pump Lift M ft Percent Load gph lph 3 7 12 25 10 5 39 7 50 19 5 73 8 75 23 7 89 7 100 31 2 118 1 Refer to Emissions Data Sheet for maximum fuel flow for EPA and SCAQMD permitting purposes STANDBY Coolant Flow per Minute gpm lpm 114 1 432 Heat Rejection to Coolant BTU hr 1 198 080 Inle...

Страница 4: ...r Opt Remote Relay Panel 8 or 16 Opt 7 Day Programmable Exerciser Std Special Applications Programmable PLC Std RS 232 Std RS 485 Std All Phase Sensing DVR Std Full System Status Std Utility Monitoring Req H Transfer Switch Std 2 Wire Start Compatible Std Power Output kW Std Power Factor Std Reactive Power Std All phase AC Voltage Std All phase Currents Std Oil Pressure Std Coolant Temperature Std...

Страница 5: ...RE RUN TIME HOURS USABLE CAPACITY GAL NO TANK 10 334 32 1001 32 1001 64 2002 LEVEL 2 SOUND ENCLOSURE RUN TIME HOURS USABLE CAPACITY GAL NO TANK 10 334 32 1001 32 1001 64 2002 5 of 5 SD500 enclosure and tank configurations YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER Generac Power Systems Inc S45 W29290 HWY 59 Waukesha WI 53189 generac com 2012 Generac Power Systems Inc All rights reserved All...

Отзывы: