background image

ENGINE SPECIFICATIONS

General

Cooling System

Make

Perkins

Cooling System Type

Closed Recovery

EPA Emissions Compliance

Stationary Emergency

Water Pump

Centrifugal Type, Belt-Driven

EPA Emissions Reference

See Emissions Data Sheet

Fan Type

Pusher

Cylinder #

6

Fan Speed (rpm)

1658 rpm

Type

In-Line

Fan Diameter mm (in.)

927 (36.5)

Displacement - L

15.2

Coolant Heater Standard Wattage

1500

Bore - mm (in.)

137 (5.39)

Coolant Heater Standard Voltage

120VAC

Stroke - mm (in.)

171 (6.73)

Compression Ratio

16.0:1

Fuel System

Intake Air Method

Turbocharged/Aftercooled

Fuel Type

Ultra Low Sulfur Diesel #2

Cylinder Head Type

4 Valve

Fuel Specifications

ASTM

Piston Type

Aluminum

Fuel Filtering (microns)

Primary 10 - Secondary 2

Connecting Rod Type

I-Beam Section

Fuel Injection

Electronic

Fuel Pump Type

Engine Driven Gear

Engine Governing

Injector Type

MEUI

Governor

Electronic Isochronous

Engine Type

Pre-Combustion

Frequency Regulation (Steady State)

± 0.25%

Fuel Supply Line - mm (in.)

12.7 (½"NPT)

Fuel Return Line - mm (in.)

12.7 (½"NPT)

Lubrication System

Oil Pump Type

Gear

Engine Electrical  System

Oil Filter Type

Full-Flow Cartridge

System Voltage

24VDC

Crankcase Capacity - L (Gal)

60 (15.8)

Battery Charging Alternator

70 Amps at 24V

Battery Size (at 0ºC)

1155 CCA

Battery Group

8D

Battery Voltage

(2) - 12VDC

Ground Polarity

Negative

ALTERNATOR SPECIFICATIONS

Standard Model

WEG

Voltage Regulator Type

Digital

Poles

4

Number of Sensed Phases

All

Field Type

Revolving

Regulation Accuracy (Steady State)

± 1%

Insulation Class - Rotor

H

Insulation Class - Stator

H

Total Harmonic Distortion

< 3%

Telephone Interference Factor (TIF)

< 50

Standard Excitation

Permanent Magnet

Bearings

Single Sealed Cartridge

Coupling

Direct, Flexible Disc

Load Capacity - Standby

100%

Prototype Short Circuit Test

Yes

CODES AND STANDARDS COMPLIANCE (WHERE APPLICABLE)

NFPA 99

BS5514

NFPA 110

SAE J1349

ISO 8528-5

DIN6271

ISO 1708A.5

IEEE C62.41 TESTING

ISO 3046

NEMA ICS 1

UL2200

2 of 5

Rating Definitions:
Standby – Applicable for a varying emergency load for the duration of a utility power outage with no overload capability. (Max. load factor = 70%)  
Prime – Applicable for supplying power to a varying load in lieu of utility for an unlimited amount of running time. (Max. load factor = 80%) A 10% overload capacity is available for 1 out of 
every 12 hours.

SD500 

application and engineering data

500 kW Diesel

Содержание SD500

Страница 1: ... COMPLIANT 4 MEETS EPA STANDARDS INDUSTRIAL TESTED GENERAC APPROVED 4 ENSURES INDUSTRIAL STANDARDS POWER MATCHED OUTPUT 4 ENGINEERED FOR PERFORMANCE INDUSTRIAL GRADE 4 IMPROVES LONGEVITY AND RELIABILITY Alternator TWO THIRDS PITCH 4 ELIMINATES HARMFUL 3RD HARMONIC LAYER WOUND ROTOR STATOR 4 IMPROVES COOLING CLASS H MATERIALS 4 HEAT TOLERANT DESIGN DIGITAL 3 PHASE VOLTAGE CONTROL 4 FAST AND ACCURAT...

Страница 2: ...em Oil Filter Type Full Flow Cartridge System Voltage 24VDC Crankcase Capacity L Gal 60 15 8 Battery Charging Alternator 70 Amps at 24V Battery Size at 0ºC 1155 CCA Battery Group 8D Battery Voltage 2 12VDC Ground Polarity Negative ALTERNATOR SPECIFICATIONS Standard Model WEG Voltage Regulator Type Digital Poles 4 Number of Sensed Phases All Field Type Revolving Regulation Accuracy Steady State 1 I...

Страница 3: ...ze 2 832 757 1136 1514 1893 2271 2650 Upsize 2 723 571 857 1143 1429 1714 2000 Fuel Consumption Rates STANDBY Fuel Pump Lift M ft Percent Load gph lph 3 7 12 25 10 5 39 7 50 19 5 73 8 75 23 7 89 7 100 31 2 118 1 Refer to Emissions Data Sheet for maximum fuel flow for EPA and SCAQMD permitting purposes STANDBY Coolant Flow per Minute gpm lpm 114 1 432 Heat Rejection to Coolant BTU hr 1 198 080 Inle...

Страница 4: ...r Opt Remote Relay Panel 8 or 16 Opt 7 Day Programmable Exerciser Std Special Applications Programmable PLC Std RS 232 Std RS 485 Std All Phase Sensing DVR Std Full System Status Std Utility Monitoring Req H Transfer Switch Std 2 Wire Start Compatible Std Power Output kW Std Power Factor Std Reactive Power Std All phase AC Voltage Std All phase Currents Std Oil Pressure Std Coolant Temperature Std...

Страница 5: ...RE RUN TIME HOURS USABLE CAPACITY GAL NO TANK 10 334 32 1001 32 1001 64 2002 LEVEL 2 SOUND ENCLOSURE RUN TIME HOURS USABLE CAPACITY GAL NO TANK 10 334 32 1001 32 1001 64 2002 5 of 5 SD500 enclosure and tank configurations YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER Generac Power Systems Inc S45 W29290 HWY 59 Waukesha WI 53189 generac com 2012 Generac Power Systems Inc All rights reserved All...

Отзывы: