8400 BaseLine D | Software Manual
Commissioning
Commissioning of the drive application with the »Engineer«
The device inputs and outputs called system blocks at Lenze are the interface of the
application towards the peripherals of the controller, e.g. the digital and analog I/Os (
"LS_DigitalInput, LS_DigitalOutput, LS_AnalogInput").
This is how you can follow, for instance, the origin of the main setpoint in the »Engineer«.
Based on the "Application parameter" tab shown before, select the following path:
Click the "Signal flow" button.
The dialog box "Overview --> Signal flow" appears (see below).
Here you find the "Analog input 1" button (see marking).
By the selection of the signal source (terminal control 0) this input is entered as source
of the main setpoint:
[3-7]
Signal sources of the TA "Speed closed-loop control", path: "Application parameters" tab --> "Signal flow" button
Click the "Main setpoint" button. A dialog window opens which contains further details
on the origin
(terminal X4/A1U) and parameter setting (offset, C026 / gain, C027):