8400 BaseLine D | Software Manual
Drive Application
Interface description of the drive application
144
L
Firmware 03.00 - DMS EN 5.0 - 07/2009
bMPOTUp
bMPOTDown
bMPOTInAct
bMPOTEnable
BOOL
---> Motor potentiometer function
The application is provided with an integrated motor potentiometer. This function
can be switched on/off via the parameters C701/11 or C806 = 1.
When the function is switched on, the motor potentiometer is connected to the
main setpoint path and thus acts as signal source for the main speed setpoint.
This setpoint can be ramped up and down by means of the digital control inputs
bMPOTUp and bMPOTDown via a parameterisable ramp time (C802, C803).
bCInh
BOOL
There are several options to inhibit the controller:
• Terminal 28 (RFG)
This signal acts fail-safe and always inhibits the controller.
FALSE : controller inhibit is active
• Control parameter C2/16.
0: controller inhibit is active
• bCinh at the control input of the application
TRUE: controller inhibit is active
As long as one of these controller inhibit sources is set, the drive remains in the
controller inhibited status.
The reason for the "controller is inhibited" status can be detected via the C0158
parameter.
When controller inhibit is set, the drive loses its torque, the machine is coasting.
When the controller inhibit request is reset, the drive synchronises to the actual
speed. For this purpose,
• an automatic flying restart function of the device is activated, if required (see
parameter C990)
• the actual speed from the motor model of the motor control is used for
synchronisation for vector control without feedback.
bFailReset
BOOL
A pending error can be reset by a LOW-HIGH edge (Lenze setting, linkage with
terminal X4/RFR) of this digital control signal if the cause of the fault has been
eliminated.
If the fault still exists, the error status remains unchanged.
bSetError1
bSetError2
BOOL
bStatus_Bit0
bStatus_Bit2
..
bStatus_Bit5
bStatus_Bit14
bStatus_Bit15
BOOL
Identifier/data type