Firmware 03.00 - DMS EN 5.0 - 07/2009
L
59
8400 BaseLine D | Software Manual
Drive control (DCTRL)
Controller commands
Quick saving at the push of a button
This function serves to save all available parameter sets at any time by pushing a button.
Automatic saving of parameter changes
When you activate the automatic saving function with code
change is saved in the memory module. Thus, manual saving of parameter sets is not
required anymore.
Manual saving of parameter sets
This procedure serves to save either the parameter set 1 or all parameter sets via the
subcodes of code
.
When
= "1", the parameter set 1 is saved in the controller.
When
= "1", all parameter sets are saved in the controller.
How to proceed:
1. Keep the entry button pressed for 3
seconds.
2. When "SAVE" is blinking, your
parameter sets are saved with
mains failure protection.
3. You can continue your work. "SAVE"
will disappear from the display after
approximately 2 seconds.
Stop!
Activating this function is not permissible if parameters are changed very
frequently (e.g. in case of cyclic writing of parameters via a bus system).
The maximum service life of the memory module amounts to one million
writing cycles. Make sure that this value will not be reached.
B
ESC
C
D
E
F
A
8888
3 sec
SAVE