8400 StateLine C | Reference manual
Diagnostics & error management
Monitoring
394
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
9.6
Monitoring
The controller is provided with various monitoring functions which protect the drive
against impermissible operating conditions.
If a monitoring function responds,
– an entry will be made into the
Logbook
of the controller,
– the response (TroubleQSP, Warning, Fault, etc.) set for this monitoring function will
be triggered,
– the status of the internal device control changes according to the selected response,
controller inhibit is set, and the "DRIVE ERROR" LED on the front of the controller goes
on:
Related topics:
LED status displays of the device status
(
382)
Device state machine and device statuses
(
86)
Device overload monitoring (Ixt)
(
233)
Motor load monitoring (I2xt)
(
234)
Motor temperature monitoring (PTC)
(
236)
Brake resistor monitoring (I2xt)
(
237)
Motor phase failure monitoring
(
239)
Mains phase failure monitoring
(
242)
Maximum current monitoring
(
242)
Maximum torque monitoring
(
243)
Encoder open-circuit monitoring
(
244)
Response
Entry in the
logbook
Display in
C00168
Pulse inhibit Controller
inhibit
Acknowledge
ment
required
LED
"DRIVE ERROR"
None
OFF
Fault
;
;
;
;
;
Trouble
;
;
;
;
(after 0.5 s)
TroubleQSP
;
;
;
Warning
Locked
;
;
;
Warning
;
;
Information
;
OFF
System error
;
;
;
;
Mains
switching
is required!
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]