8400 StateLine C | Reference manual
Motor control (MCTRL)
Internal interfaces | system block "LS_MotorInterface"
250
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
bIdentificationActive
BOOL
"Motor parameter identification active" status signal
Automatic motor data identification (
112)
TRUE Motor parameter identification is active
bFlyingSyncActive
BOOL
"Flying restart function active" status signal
Flying restart function (
200)
TRUE Flying restart function is active
bHlgLoad
BOOL
Control signal for an additional loading function of the ramp function generator
•
L_NSet_1
.
bExternalCINH
• To enable the ramp function generator to follow automatically when the
controller is inhibited, for jerk-free setpoint connection.
TRUE Set the ramp function generator to a setpoint of
nHlgSetValue_a
nHlgSetValue_a
INT
Setpoint for an additional loading function of the ramp function generator
•
L_NSet_1
.
nCInhVal_a
• For speed-controlled drive tasks, the current actual speed value (e.g. in case of an
active pulse inhibit, flying restart function, controller inhibit) is provided at this
output.
• Scaling: 16384
≡
100 % reference speed (
C00011
)
bHlgStop
BOOL
Control signal for stopping the ramp function generator (
L_NSet_1
)
TRUE Stop the ramp function generator
Identifier
DIS code | data type
Value/meaning