Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
161
8400 StateLine C | Reference manual
Motor control (MCTRL)
Sensorless vector control (SLVC)
In comparison to the V/f characteristic control without feedback, the following can be
achieved by means of sensorless vector control SLVC:
A higher maximum torque throughout the entire speed range
A higher speed accuracy
A higher concentricity factor
A higher level of efficiency
The implementation of torque-actuated operation with speed limitation
The limitation of the maximum torque in motor and generator mode for speed-
actuated operation
5.7.1
Parameterisation dialog/signal flow
Proceed as follows to open the dialog for parameterising the motor control:
1. »Engineer« Go to the
Project view
and select the 8400 StateLine controller.
2. Go to
Workspace
and change to the
Application parameters
tab.
3. Select the motor control "4: SLVC: Vector control" from the
Overview
dialog level in
the
Motor control
list field (
C00006
):
4. Click the
Motor control vector
button to change to the
Overview
Motor control
vector
dialog box.
• This dialog level only shows a simplified signal flow with the most important
parameters.
• When you click the
>>More details
button in the left-most position, a signal
flow with more details/parameters is displayed, as shown in the following
subchapter.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]