Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
209
8400 StateLine C | Reference manual
Motor control (MCTRL)
Parameterisable additional functions
5.9.7
Oscillation damping
Mechanical oscillations are undesirable effects in every process and they may have an
adverse effect on the single system components and/or the production output.
Mechanical oscillations in the form of speed oscillations are suppressed by the oscillation
damping function.
Mechanical oscillations may occur:
In the voltage range (output voltage is lower than max. voltage)
– Here, the oscillations occur in no-load operation.
– Here, speeds of 40 ... 80 % of the rated speed are typical.
– See subchapter "
Oscillation damping voltage range
".
(
210)
In the field weakening range (output voltage has reached maximum voltage)
– Here, the oscillations occur in no-load operation and with load.
– Here, speeds higher than the rated speed are typical, especially when the output
frequency is close to the mains frequency.
– See subchapter "
Oscillation damping in the field weakening range
".
(
211)