Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
629
8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00632
C00632
C00633
Parameter | Name:
C00632 | L_NSet_1: Max.SkipFrq.
Data type: INTEGER_16
Index: 23943
d
= 5D87
h
Maximum limit values for the speed blocking zones
• Selection of the maximum limit values for the blocking zones in which the speed must not be constant.
Setting range
(min. value | unit | max. value)
0.00
%
199.99
Subcodes
Lenze setting
Info
C00632/1
0.00 %
L_NSet_1
: Blocking speed1 max
C00632/2
0.00 %
L_NSet_1
: Blocking speed2 max
C00632/3
0.00 %
L_NSet_1
: Blocking speed3 max
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00633 | L_NSet_1: Min.SkipFrq.
Data type: INTEGER_16
Index: 23942
d
= 5D86
h
Minimum limit values for the speed blocking zones
• Selection of the minimum limit values for the blocking zones in which the speed must not be constant.
Setting range
(min. value | unit | max. value)
0.00
%
199.99
Subcodes
Lenze setting
Info
C00633/1
0.00 %
L_NSet_1
: Blocking speed1 min
C00633/2
0.00 %
L_NSet_1
: Blocking speed2 min
C00633/3
0.00 %
L_NSet_1
: Blocking speed3 min
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100