8400 StateLine C | Reference manual
Function library
Function blocks | L_DFlipFlop_1
794
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
If the
bClr
input = TRUE:
Due to the priority
bClr
>
bClk
,
bD
the
bOut
output signal can be set any time to the
FALSE
status by the
bClr
input signal = TRUE.
The output signal is kept in this status independent of the other input signals.