Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
355
8400 StateLine C | Reference manual
Basic drive functions (MCK)
Internal interfaces | System block "LS_MotionControlKernel"
Outputs
bMBrakeStartValue2
BOOL
(from version 11.00.00)
Holding brake control
:
Selection of the torque feedforward control value for manual specification of the
feedforward control value
• Only effective if bit 4 in
C02582
is set to "1".
Feedforward control of the motor before release
FALSE Starting value 1 (
C02581/4
) active.
TRUE Starting value 2 (
C02581/5
) active.
nMBrakeAddValue_a
INT
(from version 11.00.00)
Holding brake control
:
Additive feedforward control value (speed or torque) in [%] for torque feedforward
control when the respective control mode is started
• For speed control: 100 %
≡
reference speed (
C00011
)
• For torque control: 100 %
≡
maximum torque (
C00057
)
Feedforward control of the motor before release
bMBrakeApplied
BOOL
(from version 11.00.00)
Holding brake control
:
Input for status detection via switching contacts at the brake
• Only effective if bit 5 in
C02582
is set to "1".
FALSE Brake is released.
TRUE Brake is applied.
Identifier
Data type
Value/meaning
Control and setpoint signals for motor control
The following outputs are used to transfer control signals and setpoints to the internal motor control function
(
LS_MotorInterface
).
bPosCtrlOn_
Outputs have no function on the 8400 StateLine!
bDeltaPosOn_
dnDeltaPos_p_
dnPosSetValue_p_
bPosDerivativeOn_
bMotorRefOffsetOn_
dnMotorRefOffset_p_
bQspOn_
BOOL
TRUE Activate quick stop
nPWMAngleOffset_a_
INT
Angular offset input
bSpeedCtrlIOn_
BOOL
TRUE Set I-component of speed controller.
nSpeedCtrlI_a_
INT
I-component of the speed controller
nSpeedSetValue_a_
INT
Main setpoint of speed
bTorqueModeOn_
BOOL
TRUE Switch on torque-guided operation.
nTorqueSetValue_a_
INT
Torque setpoint
bDcBrakeOn_
BOOL
TRUE Activate DC-injection braking.
bTorqueLimitAdaptOn_
Outputs have no function on the 8400 StateLine!
nTorqueLimitAdapt_a_
Identifier
Data type
Information/possible settings
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]