8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00073
C00073
C00074
C00075
C00076
Parameter | Name:
C00073 | Imax/M controller gain
Data type: UNSIGNED_16
Index: 24502
d
= 5FB6
h
Amplification factor Vp of certain controllers for different motor control modes
Setting range
(min. value | unit | max. value)
0.00
100.00
Subcodes
Lenze setting
Info
C00073/1
0.25
VFC
: Vp Imax controller
• After the motor to be used has been selected from the
motor catalogue, the suitable value can be entered
automatically.
C00073/2
1.25
SLVC
: Vp torque controller
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 100
Parameter | Name:
C00074 | Reset time Imax/M controller
Data type: UNSIGNED_16
Index: 24501
d
= 5FB5
h
Reset time Ti of certain controllers for different motor control modes
Setting range
(min. value | unit | max. value)
0
ms
9990
Subcodes
Lenze setting
Info
C00074/1
65 ms
VFC
: Ti Imax controller
C00074/2
30 ms
SLVC
: Ti torque controller
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 1
Parameter | Name:
C00075 | Vp current controller
Data type: UNSIGNED_16
Index: 24500
d
= 5FB4
h
Gain factor Vp of the current controller for certain inverter functions (parameter identification, flying restart circuit)
• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically.
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
V/A
500.00
7.00 V/A
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 100
Parameter | Name:
C00076 | Ti current controller
Data type: UNSIGNED_16
Index: 24499
d
= 5FB3
h
Reset time Ti of the current controller for certain inverter functions (parameter identification, flying restart circuit)
• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically.
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
ms
500.00
10.61 ms
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 100