Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
585
8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00354
C00354
C00355
Parameter | Name:
C00354 | COBID
Data type: UNSIGNED_32
Index: 24221
d
= 5E9D
h
Setting of the default COBID according to CANopen
• A change in the COBID will not be effective until a CAN reset node is performed.
System bus "CAN on board"
Setting range
(min. hex value | max. hex value)
0x00000000
0xFFFFFFFF
Value is bit-coded:
Info
Bit 0 COBID Bit0
• Bit 0 ... 10: COB-ID
• Bit 11 ... 30: Reserved
• Bit 31: PDO invalid (is not transmitted)
... ...
Bit 31 PDO invalid
Subcodes
Lenze setting
Info
C00354/1
513
COBID CAN1_IN
C00354/2
385
COBID CAN1_OUT
C00354/3
769
COBID CAN2_IN
C00354/4
641
COBID CAN2_OUT
C00354/5
1025
COBID CAN3_IN
C00354/6
897
COBID CAN3_OUT
;
Read access
;
Write access
CINH
PLC STOP
No transfer
;
COM
MOT
Parameter | Name:
C00355 | Active COBID
Data type: UNSIGNED_16
Index: 24220
d
= 5E9C
h
Display of the COBID of the PDOs that is active in the CAN stack
System bus "CAN on board"
Display range
(min. value | unit | max. value)
0
2047
Subcodes
Info
C00355/1
Active COBID CAN1_IN
C00355/2
Active COBID CAN1_OUT
C00355/3
Active COBID CAN2_IN
C00355/4
Active COBID CAN2_OUT
C00355/5
Active COBID CAN3_IN
C00355/6
Active COBID CAN3_OUT
;
Read access
Write access
CINH
PLC STOP
;
No transfer
;
COM
MOT
Scaling factor: 1