8400 StateLine C | Reference manual
Introduction: Parameterising the controller
Device access protection
46
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
Deactivating the device personalisation/changing the binding ID
The device personalisation is simply deactivated by deleting the set binding ID. If you
would like to change the set binding ID, delete the set binding ID first. Then set the desired
new binding ID.
How to delete the binding ID:
1. Enter the set binding ID in
C00505/2
.
• If the controller and the memory module have different binding IDs, enter the
binding ID of the memory module to delete the binding IDs of both
components.
2. Execute "Delete binding ID" device command
C00002/30
= "1: On / start"
• After a successful deletion, status OFF is displayed in
C00505/2
.
2.4.3
Unlocking the controller with a MasterPin
Every controller has an individual master password, the MasterPin. A controller which is
locked due to password mechanism can reach the delivery status again if the MasterPin is
entered.
How to re-establish the delivery status:
1. Inhibit the controller if it is enabled, e.g. via the
C00002/16
device command.
2. Enter the MasterPin in
C00505/1
.
• The last six digits of the serial number of the memory module represent the
MasterPin.
3. Execute "Check MasterPin" device command
C00002/28
= "1: On / start"
Stop!
If the MasterPin is entered, the parameter set both in the controller and in the
memory module is reset to the Lenze setting!
• Customised parameterisation will be permanently lost and must be
recreated!
• The reset to the Lenze setting may lead to unexpected level changes at the
I/O terminals (e.g. brake control)!