8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00364
588
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
C00364
C00366
Parameter | Name:
C00364 | CAN MessageError
Data type: UNSIGNED_8
Index: 24211
d
= 5E93
h
System bus "CAN on board"
Selection list
(read only)
0 No Error
1 StuffError
2 FormError
3 AckError
4 Bit1Error
5 Bit0Error
6 CRCError
7 Reserved
;
Read access
Write access
CINH
PLC STOP
;
No transfer
;
COM
MOT
Scaling factor: 1
Parameter | Name:
C00366 | Number of CAN SDO channels
Data type: UNSIGNED_8
Index: 24209
d
= 5E91
h
Change in function from version 05.01.00
Selection of the number of active parameter data channels
•
Up to and including version 05.00.00
, parameter data channels 1 and 2 are activated in the Lenze setting.
•
From version 05.01.00
, only parameter data channel 1 is activated according to CANopen in the Lenze setting. To
activate both parameter data channels according to the previous behaviour, select "2 SDO Lenze".
System bus "CAN on board"
Selection list
(Lenze setting printed in bold)
0 1 SDO CANOpen
1 2 SDO Lenze
;
Read access
;
Write access
CINH
PLC STOP
No transfer
;
COM
MOT
Scaling factor: 1