Memory problems
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 7, “Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530,” on page 201 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
Trained service technician.
v
Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Symptom
Action
The amount of system memory
that is displayed is less than the
amount of installed physical
memory.
1.
Make sure that:
v
No error LEDs are lit on the control-panel assembly or on the system board.
v
Memory mirroring does not account for the discrepancy.
v
The memory modules are seated correctly.
v
You have installed the correct type of memory.
v
All DIMMs are enabled. The server might have automatically disabled a
DIMM when it detected a problem.
2.
Check the POST error log for error message 289:
v
If a DIMM was disabled by a system-management interrupt (SMI), replace
the DIMM.
3.
Run memory diagnostics (see “Running the diagnostic programs” on page 67).
4.
Make sure that there is no memory mismatch when the server is over the
minimum memory configuration (one 1 GB DIMM) and that you have
installed the correct number of DIMMs.
5.
Reseat the DIMMs.
6.
Replace the following components one at a time, in the order shown, restarting
the server each time:
a.
DIMMs
b.
(Trained service technician only) System board
Multiple rows of DIMMs in a
branch are identified as failing.
1.
Reseat the DIMMs; then, restart the server.
2.
Replace the lowest-numbered DIMM pair of those that are identified; then,
restart the server. Repeat as necessary.
3.
(Trained service technician only) Replace the system board.
54
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Hardware Maintenance Manual
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...