You can install full-length adapters that are included in the supported options list in slots 1 through 5
(depending on your model).
v
The 32-bit slots 4 and 5 support 5.0 V keyed PCI adapters; they do not support 3.3 V keyed adapters.
Universal adapters are supported in slots 4 and 5 if they are universally keyed.
v
The server scans PCI Express Gen 2 x8 (x8) slot 1, PCI Express Gen 2 x8 (x8) slot 2, PCI Express Gen 2
x4 (x4) slot 3, and PCI slots 4 and 5 to assign system resources. Then, the server starts the PCI devices
in the following order, if you have not changed the default startup sequence: PCI Express Gen 2 x8 (x8)
slot 1, PCI Express Gen 2 x8 (x8) slot 2, PCI Express Gen 2 x4 (x4) slot 3, PCI slot 4, and PCI slot 5.
v
See http://www.lenovo.com/thinkserver and click the
Options
tab for a list of supported options.
To install an adapter, complete the following steps.
Note:
Static electricity that is released to internal server components when the server is powered-on
might cause the server to stop, which might result in the loss of data. To avoid this potential problem,
always use an electrostatic-discharge wrist strap or other grounding system when you work inside the
server with the power on.
To install an adapter, complete the following steps:
1.
Read the safety information that begins on page 1.
2.
Turn off the server and peripheral devices and disconnect all external cables and power cords; then,
remove the side cover. See “Removing the side cover” on page 130.
3.
Follow the cabling instructions, if any, that come with the adapter. Route the adapter cables before
you install the adapter.
4.
Follow the instructions that come with the adapter to set jumpers or switches, if any.
5.
Rotate the rear adapter-retention bracket to the open position and remove it from the server.
6.
Remove the screw that secures the expansion-slot cover to the chassis. Store the expansion-slot cover
and screw in a safe place for future use.
Note:
Expansion-slot covers must be installed on all vacant slots. This maintains the electronic
emissions standards of the server and ensures proper ventilation of server components.
154
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Hardware Maintenance Manual
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...