System-board switches and jumpers
The following illustration shows the switches and jumpers on the system board.
Microprocessor
Heatsink
Orientation
DIMMs
DIMMs
The following table describes the jumpers on the system board.
Table 6. System board jumpers
Jumper number
Jumper name
Jumper setting
JP1
Clear CMOS jumper
1
v
Pins 1 and 2: Keep CMOS data
(default).
v
Pins 2 and 3: Clear CMOS data
(including power-on password and
administrator password)
JP6
Boot block jumper
2
v
Pins 1 and 2: Boot from primary
BIOS page (default) .
v
Pins 2 and 3: Boot from backup
BIOS page.
Notes:
1.
If no jumper is present, the server responds as if the pins are set to 1 and 2.
2.
Changing the position of the UEFI boot recovery jumper from pins 1 and 2 to pins 2 and 3 before the server is
turned on alters which flash ROM page is loaded. Do not change the jumper pin position after the server is
turned on. This can cause an unpredictable problem.
Important:
1.
Before you change any switch settings or move any jumpers, turn off the server; then, disconnect all
power cords and external cables. Review the information in“Handling static-sensitive devices” on
page 129 and “Turning off the server” on page 125.
2.
Any system-board switch or jumper blocks that are not shown in the illustrations in this document
are reserved.
120
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Hardware Maintenance Manual
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...