![background image](http://html.mh-extra.com/html/lenovo/thinkserver-ts200-6522/thinkserver-ts200-6522_hardware-maintenance-manual_203063185.webp)
3.
Reinstall any adapters that you removed earlier.
4.
Close the front and rear adapter retention brackets.
5.
Go to “Completing the FRU replacement” on page 190.
Replacing the hot-swap power supply cage
Use the following procedures to replace the power supply cage. This procedure applies only to server
models that have a hot-swap power supply.
Removing the hot-swap power supply cage
To remove the power supply cage, complete the following steps:
1.
Read the safety information that begins on page 1.
2.
Turn off the server and all attached devices; then, disconnect all power cords and external cables.
3.
Unlock and remove the side cover (see “Removing the side cover” on page 130).
4.
Remove the hot-swap power supplies (see “Replacing a non-hot-swap power supply” on page 180).
Note:
It might be helpful to lay the server on its side for the remainder of this procedure.
5.
Disconnect the cables from the power supply cage to the system board and all internal components.
6.
Remove the four black screws that secure the power supply cage to the chassis; then, slide the cage
toward the front of the server to disengage the retaining clips
1
from the top of the chassis and lift
the cage out of the chassis.
7.
If you are instructed to return the power supply cage, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Installing the hot-swap power supply cage
This procedure applies only to server models that have hot-swap power supply.
To install the hot-swap power supply cage, complete the following steps:
1.
Place the power supply cage into the chassis and slide it toward the rear of the server until the
retaining clips
1
engage the top of the chassis.
Chapter 6. Replacing FRUs
177
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...