6.
If you are instructed to return the DIMM, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
Installing a memory module
See “System-board internal connectors” on page 118 for the location of the DIMM connectors on the
system board.
Attention:
Static electricity that is released to internal server components when the server is powered-on
might cause the server to stop, which could result in the loss of data. To avoid this potential problem,
always use an electrostatic-discharge wrist strap or other grounding system when working inside the
server with the power on.
To install a DIMM, complete the following steps:
1.
Read the safety information that begins on page 1.
2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables, if
necessary.
3.
Remove the cover (see “Removing the side cover” on page 130).
4.
Open the retaining clip on each end of the DIMM connector.
Attention:
To avoid breaking the retaining clips or damaging the DIMM connectors, open and close
the clips gently.
138
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Hardware Maintenance Manual
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...