2.
Squeeze the spring clips
1
on the sides of the front USB connector assembly and insert the assembly
into the housing through the back of the housing.
3.
Place the bottom edge of the housing into the bottom of the opening in the chassis; then, tilt the top
of the housing into position until it clicks into place.
4.
Reroute and connect the front USB cable to the front USB connector on the system board (see
“System-board internal connectors” on page 118 for the location of the front USB connector).
5.
Go to “Completing the FRU replacement” on page 190.
Replacing the rear adapter retention bracket
Use the following procedures to replace the rear adapter-retention bracket.
Removing the rear adapter retention bracket
To remove the rear adapter retention bracket, complete the following steps:
1.
Turn off the server and all attached devices; then, disconnect all power cords and external cables.
2.
Unlock and remove the side cover (see “Removing the side cover” on page 130).
3.
Remove all adapters (if necessary) and place the adapters on static-protective surface.
Note:
You might find it helpful to note where each adapter is installed before you remove the
adapters.
4.
Release the rear adapter-retention bracket by lifting up on the rear adapter-retention bracket, and
rotate the bracket partially toward the closed position.
5.
Grasp the bracket on one side at the hinge point and pull inward (while you rotate the bracket
slightly toward the front of the server) until the bracket
1
is free of the hinge pin
2
; then, grasp
the bracket on the other side at the hinge point, pull inward until the bracket is free of the hinge pin,
and remove the rear adapter-retention bracket from the server.
Chapter 6. Replacing FRUs
175
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...