4.
Remove the lower bezel, and then remove the upper bezel (see “Removing the two-piece bezel” on
page 131).
5.
Slide the drives in bay 1 and bay 2 forward slightly (see “Removing a DVD drive” on page 142 for
more information). It is not necessary to remove these drives.
6.
If the server has hot-swap power supplies, remove the power supplies and the power supply cage
(see “Replacing the hot-swap power supply cage” on page 177).
7.
Disconnect the front-panel assembly cable from the system board, and note the routing of the cable
(see “System-board internal connectors” on page 118 for the location of the front-panel connector).
8.
Press up on the release tab of the front-panel assembly
1
and pull the assembly toward the rear of
the server; then, remove the front-panel assembly from the chassis.
9.
If you are instructed to return the front-panel assembly, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Installing the front-panel assembly
To install the front-panel assembly, complete the following steps:
1.
Position the front end of the front-panel assembly in the channel above drive bay 1 on the left side of
the chassis.
2.
Push the front-panel assembly
1
toward the front of the chassis until it clicks into place.
3.
Reroute and connect the front-panel assembly cable to the system board (see “System-board internal
connectors” on page 118 for the location of the front-panel connector).
4.
If the server has hot-swap power supplies, install the power supply cage and the power supplies (see
“Replacing the hot-swap power supply cage” on page 177).
5.
Push the drives in bay 1 and bay 2 into the drive bays (see “Installing a DVD drive” on page 142 for
more information).
6.
Go to “Completing the FRU replacement” on page 190.
Chapter 6. Replacing FRUs
173
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...