Installing a hot-swap hard disk drive
This procedure applies only to server models that have hot-swap hard disk drives. Before you install a
hot-swap hard disk drive, read the following information:
v
The hot-swap drives must be either all SAS hard disk drives or all SATA hard disk drives; the two
types cannot be combined.
v
Inspect the drive tray for signs of damage.
v
To maintain proper system cooling, do not operate the server for more than 10 minutes without either
a drive or a filler panel installed in each drive bay.
v
You do not have to turn off the server to install hot-swap drives in the hot-swap drive bays.
v
See “Replacing internal drives” on page 140 for additional information.
To install a hot-swap hard disk drive (based on your model), complete the following steps.
1.
Touch the static-protective package that contains the drive to any unpainted metal surface on the
server; then, remove the drive from the package and place it on a static-protective surface.
2.
Make sure that the drive tray handle is in the open position.
3.
Align the drive assembly with the guide rails in the bay; then, carefully slide the drive assembly
1
into the drive bay until the drive stops.
4.
Rotate the drive tray handle to the closed position
2
.
5.
Check the hard disk drive status indicator to make sure that the hard disk drive is operating correctly.
(You might have to restart the server for the drive to be recognized.) If the amber hard disk drive
status LED for a drive is lit continuously, it indicates that the drive is faulty and must be replaced. If
the green hard disk drive activity LED is flashing, this indicates that the drive is being accessed.
148
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Hardware Maintenance Manual
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...