Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
SeeChapter 7, “Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530,” on page 201 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
A PCI SERR has occurred on
system %1.
(%1 = CIM_ComputerSystem.
ElementName)
Error
A PCI SERR has occurred.
(Sensor = One of PCI Err)
1.
Check the extender-card
LEDs.
2.
Reseat the affected adapters
and extender card.
3.
Update the server and adapter
firmware (UEFI and IMM).
Important:
Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.
4.
Remove both adapters.
5.
Replace the PCIe adapter.
6.
Replace the extender card.
7.
(Trained service technician
only) Replace the system
board.
Fault in slot System board on
system %1.
(%1 = CIM_ComputerSystem.
ElementName)
Error
1.
Check the extender-card
LEDs.
2.
Reseat the affected adapters
and extender card.
3.
Update the server and adapter
firmware (UEFI and IMM).
Important:
Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.
4.
Remove both adapters.
5.
Replace the PCIe adapter.
6.
Replace the extender card.
7.
(Trained service technician
only) Replace the system
board.
Chapter 4. Diagnostics
41
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...