Integrated management module (IMM) error messages
The following table describes the IMM error messages and suggested actions to correct the detected
problems.
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
SeeChapter 7, “Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530,” on page 201 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Message
Severity
Description
Action
Numeric sensor Ambient Temp
going high (upper critical) has
asserted.
Error
An upper critical sensor
going high has asserted.
Reduce the ambient temperature.
Numeric sensor Ambient Temp
going high (upper non-recoverable)
has asserted.
Error
An upper nonrecoverable
sensor going high has
asserted.
Reduce the ambient temperature.
Numeric sensor Planar 3.3V going
low (lower critical) has asserted.
Error
A lower critical sensor going
low has asserted.
(Trained service technician only)
Replace the system board.
Numeric sensor Planar 3.3V going
high (upper critical) has asserted.
Error
An upper critical sensor
going high has asserted.
(Trained service technician only)
Replace the system board.
Numeric sensor Planar 5V going
low (lower critical) has asserted.
Error
A lower critical sensor going
low has asserted.
(Trained service technician only)
Replace the system board.
Numeric sensor Planar 5V going
high (upper critical) has asserted.
Error
An upper critical sensor
going high has asserted.
(Trained service technician only)
Replace the system board.
Numeric sensor Planar VBAT going
low (lower critical) has asserted.
Error
A lower critical sensor going
low has asserted.
Replace the 3 V battery.
Numeric sensor Fan
n
Tach going
low (lower critical) has asserted.
(
n
= fan number)
Error
A lower critical sensor going
low has asserted.
1.
Reseat the failing fan
n
, which
is indicated by a lit LED on
the fan.
2.
Replace the failing fan.
(
n
= fan number)
Chapter 4. Diagnostics
29
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...