Removing a DVD drive
To remove a DVD drive, complete the following steps:
1.
Read the safety information that begins on page 1.
2.
Turn off the server and all attached devices; then, disconnect all power cords and external cables.
3.
Unlock and remove the side cover (see “Removing the side cover” on page 130).
4.
Remove the lower bezel, and then remove the upper bezel (see “Removing the two-piece bezel” on
page 131).
5.
Disconnect the power and signal cables from the drive that is to be removed.
6.
Press and hold the blue release button on the side of the bay to release the drive; then, pull the drive
out of the front of the server.
1
Release buttons
2
Drive retainer clip
7.
Remove the drive retainer clip from the side of the drive. Save the clip to use when you install the
replacement drive.
8.
If you are instructed to return the drive, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
Installing a DVD drive
To install a DVD drive, complete the following steps:
1.
If you are replacing a removed drive with a new drive, make sure that:
v
You have all the cables and other equipment that is specified in the documentation that comes with
the new drive.
v
You have checked the instructions that come with the new drive to determine whether you must
set any switches or jumpers in the drive.
v
You have removed the blue optical drive rails from the side of the old drive and have them
available for installation on the new drive.
Note:
If you are installing a drive that contains a laser, observe the following safety precaution.
142
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Hardware Maintenance Manual
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...