v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 7, “Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530,” on page 201 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
v
Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Error code
Description
Action
3808004
IMM system event log full
v
When using out-of-band, use the IMM Web
interface or IPMItool to clear the logs from the
operating system.
v
When using the local console:
1.
Run the Setup utility.
2.
Select
System Event Log
.
3.
Select
Clear System Event Log
.
4.
Restart the server.
3818001
Core Root of Trust Measurement (CRTM)
update failed
1.
Run the Setup utility, select
Load Default
Settings
, and save the settings.
2.
(Trained service technician only) Replace the
system board.
3818002
Core Root of Trust Measurement (CRTM)
update aborted
1.
Run the Setup utility, select
Load Default
Settings
, and save the settings.
2.
(Trained service technician only) Replace the
system board.
3818003
Core Root of Trust Measurement (CRTM)
flash lock failed
1.
Run the Setup utility, select
Load Default
Settings
, and save the settings.
2.
(Trained service technician only) Replace the
system board.
3818004
Core Root of Trust Measurement (CRTM)
system error
1.
Run the Setup utility, select
Load Default
Settings
, and save the settings.
2.
(Trained service technician only) Replace the
system board.
3818005
Current Bank Core Root of Trust
Measurement (CRTM) capsule signature
invalid
1.
Run the Setup utility, select
Load Default
Settings
, and save the settings.
2.
(Trained service technician only) Replace the
system board.
3818006
Opposite bank CRTM capsule signature
invalid
1.
Switch the server firmware bank to the backup
bank (see “Starting the backup server firmware”
on page 259).
2.
Run the Setup utility, select
Load Default
Settings
, and save the settings.
3.
Switch the bank back to the primary bank.
4.
(Trained service technician only) Replace the
system board.
Chapter 4. Diagnostics
27
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...