Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 7, “Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530,” on page 201 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
v
Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Error code
Description
Action
0050001
DIMM disabled.
1.
If the server fails the POST memory test, reseat
the DIMMs.
2.
Remove and replace any DIMM for which the
associated error LED is lit (see “Replacing a
memory module” on page 134).
3.
Run the Setup utility to enable all the DIMMs.
4.
Run the DSA Preboot memory test (see “Running
the diagnostic programs” on page 67).
0051003
Uncorrectable DIMM error
1.
If the server failed the POST memory test, reseat
the DIMMs.
2.
Remove and replace any DIMM for which the
associated error LED is lit see “Replacing a
memory module” on page 134 ).
3.
Run the Setup utility to enable all the DIMMs.
4.
Run the DSA Preboot memory test (see “Running
the diagnostic programs” on page 67).
0051006
DIMM mismatch detected
Make sure that the DIMMs match and are installed in
the correct sequence (see “Replacing a memory
module” on page 134).
0051009
No memory detected.
1.
Make sure that the server contains DIMMs.
2.
Reseat the DIMMs.
3.
Install DIMMs in the correct sequence (see
“Replacing a memory module” on page 134).
005100A
No usable memory detected.
1.
Make sure that the server contains DIMMs.
2.
Reseat the DIMMs.
3.
Install DIMMs in the correct sequence (see
“Replacing a memory module” on page 134).
4.
Clear CMOS memory to re-enable all the memory
connectors (see “System-board switches and
jumpers” on page 120).
0058001
PFA threshold exceeded
1.
Update the server firmware to the latest level (see
“Updating the firmware” on page 258).
2.
Reseat the DIMMs and run the memory test (see
“Running the diagnostic programs” on page 67).
3.
Replace the failing DIMM, which is indicated by
a lit LED on the system board.
22
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Hardware Maintenance Manual
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...