Table 11. Supported RDIMM population per channel (continued)
DIMMs slots per
channel
DIMMs installed in
each channel
DIMM type
DIMM speed
Ranks per DIMM
(any combination)
3
3
Registered DDR3
ECC
800
single-rank, dual-rank
3
1
Registered DDR3
ECC
1066
quad-rank
3
2
Registered DDR3
ECC
800
quad-rank
v
The following table lists the maximum DIMM population using ranked RDIMM.
Table 12. Maximum memory population using ranked RDIMMs (depending on your model)
Number of RDIMMs
DIMM type
DIMM size
Total memory
6
single-rank RDIMMs
1 GB
6 GB
6
single-rank RDIMMs
2 GB
12 GB
6
dual-rank RDIMMs
2 GB
12 GB
4
dual-rank RDIMMs
4 GB
16 GB
4
quad-rank RDIMMs
4 GB
16 GB
6
dual-rank RDIMMs
4 GB
24 GB
4
quad-rank RDIMMs
8 GB (when available)
32 GB
v
The following table lists the RDIMM memory population rule to optimize the system performance.
Table 13. RDIMMs population rule for dual-channel symmetric mode
DIMMs
connector 1
DIMMs
connector 2
DIMMs
connector 3
DIMMs
connector 4
DIMMs
connector 5
DIMMs
connector 6
populated
empty
empty
empty
empty
empty
populated
empty
empty
populated
empty
empty
populated
populated
empty
populated
populated
empty
populated
populated
populated
populated
populated
populated
Removing a memory module
To remove a dual inline memory module (DIMM), complete the following steps:
1.
Read the safety information that begins on page 1.
2.
Turn off the server and all attached devices; then, disconnect all power cords.
3.
Unlock and remove the side cover (see “Removing the side cover” on page 130).
4.
Locate the DIMM connector that contains the DIMM that is to be replaced (see “System-board internal
connectors” on page 118 for DIMM slot locations).
Attention:
To avoid breaking the DIMM retaining clips or damaging the DIMM connectors, open
and close the clips gently.
5.
Carefully open the retaining clips on each end
2
of the DIMM connector and remove the DIMM
1
.
Chapter 6. Replacing FRUs
137
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...