In-band manual recovery method
To recover the server firmware and restore the server operation to the primary bank, complete the
following steps:
1.
Read the safety information (see “Important Safety Information” on page 1.
2.
Turn off the server, and disconnect all power cords and external cables.
3.
Unlock and remove the server cover (see “Removing the side cover” on page 130.
4.
Locate the UEFI boot recovery jumper (JP6) on the system board (see “System-board switches and
jumpers” on page 120.)
5.
Move the jumper from pins 1 and 2 to pins 2 and 3 to enable the UEFI recovery mode.
6.
Reinstall the server cover (see “Reinstalling the side cover” on page 193); then, reconnect all power
cords.
7.
Restart the server. The power-on self-test (POST) starts.
8.
Boot the server to an operating system that is supported by the firmware update package that you
downloaded.
9.
Perform the firmware update by following the instructions that are in the firmware update package
readme file.
10.
Copy the downloaded firmware update package into a directory.
11.
From a command line, type
filename
-s
, where
filename
is the name of the executable file that you
downloaded with the firmware update package.
12.
Turn off the server and disconnect all power cords and external cables, and then remove the server
cover.
13.
Move the UEFI boot recovery jumper back to the primary position (pins 1 and 2).
14.
Reinstall the server cover, and then reconnect all the power cables.
15.
Restart the server.
See “System-board switches and jumpers” on page 120 for a description of the jumpers and switches.
In-band automated boot recovery method
Note:
Use this method if the System board error LED is lit and there is a log entry or
Booting Backup
Image
is displayed on the firmware splash screen; otherwise, use the in-band manual recovery method.
1.
Boot the server to an operating system that is supported by the firmware update package that you
downloaded.
2.
Perform the firmware update by following the instructions that are in the firmware update package
readme file.
3.
Restart the server.
4.
At the firmware splash screen, press F3 when prompted to restore to the primary bank. The server
boots from the primary bank.
Out-of-band method:
See the IMM documentation.
Automated boot recovery (ABR)
If the server is booting up and the IMM detects problems with the server firmware in the primary bank,
it will automatically switch to the backup firmware bank and give you the opportunity to recover the
primary bank. To recover to the server firmware primary bank, complete the following steps:
1.
Restart the server.
2.
When the prompt press
F3 to restore to primary
is displayed, press F3 to recover the primary bank.
Pressing F3 will restart the server.
106
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Hardware Maintenance Manual
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...