v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
SeeChapter 7, “Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530,” on page 201 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Redundancy Bckup Mem Status has
been reduced.
Error
Redundancy has been lost
and is insufficient to
continue operation.
1.
Check the system-event log
for DIMM failure events
(uncorrectable or PFA) and
correct the failures.
2.
Re-enable mirroring in the
Setup utility.
IMM Network Initialization
Complete.
Info
An IMM network has
completed initialization.
No action; information only.
Certificate Authority %1 has
detected a %2 Certificate Error.
(%1 = IBM_CertificateAuthority.
CADistinguishedName;
%2 = CIM_PublicKeyCertificate.
ElementName)
Error
A problem has occurred with
the SSL Server, SSL Client, or
SSL Trusted CA certificate
that has been imported into
the IMM. The imported
certificate must contain a
public key that corresponds
to the key pair that was
previously generated by the
Generate a New Key and
Certificate Signing Request
link.
1.
Make sure that the certificate
that you are importing is
correct.
2.
Try importing the certificate
again.
Ethernet Data Rate modified from
%1 to %2 by user %3.
(%1 = CIM_EthernetPort.Speed;
%2 = CIM_EthernetPort.Speed;
%3 = user ID)
Info
A user has modified the
Ethernet port data rate.
No action; information only.
Ethernet Duplex setting modified
from %1 to %2 by user %3.
(%1 =
CIM_EthernetPort.FullDuplex;
%2 = CIM_EthernetPort.FullDuplex;
%3 = user ID)
Info
A user has modified the
Ethernet port duplex setting.
No action; information only.
Ethernet MTU setting modified
from %1 to %2 by user %3.
(%1 = CIM_EthernetPort.
ActiveMaximumTransmissionUnit;
%2 = CIM_EthernetPort.
ActiveMaximumTransmissionUnit;
%3 = user ID)
Info
A user has modified the
Ethernet port MTU setting.
No action; information only.
Ethernet Duplex setting modified
from %1 to %2 by user %3.
(%1 = CIM_EthernetPort.
NetworkAddresses;
%2 = CIM_EthernetPort.
NetworkAddresses;
%3 = user ID)
Info
A user has modified the
Ethernet port MAC address
setting.
No action; information only.
42
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Hardware Maintenance Manual
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...