v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 7, “Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530,” on page 201 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
v
Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Error code
Description
Action
3058004
Three boot failure
1.
Undo any recent system changes, such as new
settings or newly installed devices.
2.
Make sure that the server is attached to a reliable
power source.
3.
Remove all hardware that is not supported (see
http://www.lenovo.com/support.)
4.
Make sure that the operating system is not
corrupted.
5.
Run the Setup utility, save the configuration, and
then restart the server.
3108007
System configuration restored to default
settings
Information only. This is message is usually
associated with the CMOS battery clear event.
3138002
Boot configuration error
1.
Remove any recent configuration changes made
to the Setup utility.
2.
Run the Setup utility, select
Load Default
Settings
, and save the settings.
3808000
IMM communication failure
1.
Remove power from the server for 30 seconds,
and then reconnect the server to power and
restart it.
2.
Update the IMM firmware to the latest level (see
“Updating the firmware” on page 258).
3.
Make sure that the virtual media key is seated
and not damaged.
4.
(Trained service technician only) Replace the
system board.
3808002
Error updating system configuration to IMM
1.
Remove power from the server, and then
reconnect the server to power and restart it.
2.
Run the Setup utility and select
Save Settings
.
3.
Update the IMM firmware to the latest level (see
“Updating the firmware” on page 258).
3808003
Error retrieving system configuration from
IMM
1.
Remove power from the server, and then
reconnect the server to power and restart it.
2.
Run the Setup utility and select
Save Settings
.
3.
Update the IMM firmware to the latest level (see
“Updating the firmware” on page 258).
26
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Hardware Maintenance Manual
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...