![Lenovo ThinkServer TS200 6522 Скачать руководство пользователя страница 159](http://html.mh-extra.com/html/lenovo/thinkserver-ts200-6522/thinkserver-ts200-6522_hardware-maintenance-manual_203063159.webp)
Installing a simple-swap hard disk drive
This procedure applies only to server models that have simple-swap SATA hard disk drives.
Attention:
Simple-swap hard disk drives are not hot-swappable. Disconnect all power from the server
you remove or install a simple-swap hard disk drive.
To install a simple-swap hard disk drive, complete the following steps:
1.
Touch the static-protective package that contains the drive to any unpainted metal surface on the
server; then, remove the drive from the package and place it on a static-protective surface.
2.
Align the drive assembly with the guide rails in the bay.
3.
Pull the loops of the drive assembly toward each other; then, carefully slide the drive assembly into
the drive bay until it clicks into place, and release the loops.
Note:
Do not release the loops on the drive assembly until it is completely seated.
4.
Go to “Completing the FRU replacement” on page 190.
Power and signal cables for internal drives
The server uses cables to connect SATA attached, simple-swap SATA, hot-swap SATA and hot-swap SAS
devices to the power supply and to the system board. (See “System-board internal connectors” on page
118 for the location of system-board connectors.) Review the following information before connecting
power and signal cables to internal drives:
v
The drives that are preinstalled in the server come with power and signal cables attached. If you
replace any drives, remember which cable is attached to which drive.
v
When you install a drive, make sure that one of the signal cable drive connectors is connected to the
drive and that the connector at the other end of the signal cable is connected to the system board or a
compatible adapter or controller that you have installed.
v
When you route a cable, make sure that it does not block the airflow to the rear of the drives or over
the microprocessor or DIMMs.
Chapter 6. Replacing FRUs
151
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...