Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 7, “Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530,” on page 201 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
v
Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Error code
Description
Action
2018001
PCI Express uncorrected or uncorrected error
1.
Reseat all affected adapters.
2.
Update the PCI adapter firmware.
3.
Remove the adapter.
4.
Replace the following components one at a time,
in the order shown, restarting the server each
time:
a.
Adapter
b.
(Trained service technician only) System board
2018002
Option ROM resource allocation failure
Informational message that some devices might not
be initialized.
1.
If possible, rearrange the order of the adapters in
the PCI slots to change the load order of the
optional-device ROM code.
2.
Run the Setup utility, select
Startup Options
, and
change the boot priority to change the load order
of the optional-device ROM code.
3.
Run the Setup utility and disable some other
resources, if their functions are not being used, to
make more space available.
a.
Select
Startup Options -> Planar Ethernet
(PXE/DHCP)
to disable the integrated
Ethernet controller ROM.
b.
Select
Advanced Functions -> PCI Bus
Control -> PCI ROM Control Execution
to
disable the ROM of the adapter in the PCI
slots.
c.
Select
Devices and I/O Ports
to disable any of
the integrated devices.
4.
Replace the following components one at a time,
in the order shown, restarting the server each
time:
a.
Each adapter
b.
(Trained service technician only) System board
3
xx
0007 (
xx
can be 00 -
19)
Firmware fault detected, system halted
1.
Recover the server firmware to the latest level
(see “Updating the firmware” on page 258).
2.
Undo any recent configuration changes, or clear
CMOS memory to restore the settings to the
default values (see “System-board switches and
jumpers” on page 120.
3.
Remove any recently installed hardware.
24
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Hardware Maintenance Manual
Содержание ThinkServer TS200 6522
Страница 2: ......
Страница 3: ...ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 120: ...112 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 134: ...126 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 199: ...Chapter 6 Replacing FRUs 191 ...
Страница 208: ...200 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 252: ...244 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 283: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 275 ...
Страница 284: ...276 ThinkServer TS200 Types 6522 6523 6524 6525 6526 6528 6529 and 6530 Hardware Maintenance Manual ...
Страница 289: ......
Страница 290: ...Printed in USA ...